22
Installation instructions
805845UK V1.02 July 2018 - G4 Command Centre
Technical support
Tel: 0345 6 005 005 Email: service@zipindustries.co.uk www.zipwater.co.uk
Booster system
2.2 Installation procedure
Site requirements
•
Booster must only be installed in a frost-free area. Never expose booster to frost.
•
The booster is designed for wall mounted installation and must be installed with water connectors
facing upwards.
•
The booster is protected against water ingress to class IP 25.
•
The 500mm braided hoses supplied with the booster cannot be lengthened.
•
The 90
°
elbow hose ends should be fitted to the inlet and outlet connections on top of the booster.
•
The hot water outlet hose must be thermally insulated with the insulation provided.
Tilt forward
Lift up
Release
Note
Remove the wall mounting chassis from the rear of the booster for wall mounting.
Take care not
to break the
lower clips
when removing
or installing the
booster
.
!
Attach
2.3 Booster installation
see diagrams below
• To remove the mounting chassis, insert a flat blade screwdriver all the way into the lock.
• Gently angle the screwdriver upwards by approximately 10°.
• Pull the booster forwards by approximately 15°.
• Carefully pull the booster upwards to complete the removal process. Take care not to break the lower
clips.
• Attach the mounting chassis horizontally to the wall / cupboard wall.
• To install, clip the booster into the on the mounting chassis and snap into position (see installation
below).
Install