background image

Page 8 of 20 

 

801623 - Chilled HT User Guide - 7-15 - v2.00

3

LCD Screen Menu

Main Menu

Sub Menu 

Sub Menu Options

Section

Language

•  English

•  Deutsch

A

 

•  Product Info

•  System 

Faults

•  Event Log

•  Product serial 

no.

•  Lists

B

Information

Installation

•  Filter Flush

•  Filter Reset

•  Reset options

•  Calibration 

options

C

Service

Password protected

D

Security

•  Enable 

Password

•  Set Password

•  Change 

Password

E

Communication

•  Remote 

Monitor

•  Remote 

Control

•   Wifi / Bluetooth 

Options

•   Wifi / Bluetooth 

Options

F

Settings

•  Date/Time

•  Temperature

•  Filter

•  Dispense 

Times

•   12hr/24hr 

Mode

•  Cold Setpoint

•    Filter Life 

(Litres)

•    Filter Life 

(Months)

•      Cold 

Dispensing                             

G

Summary of Contents for 801623

Page 1: ...7 15 v2 00 Page 1 of 20 ZIP HydroTap G4 User Guide Tap Operation Pages 2 6 LCD Screen Menu Pages 7 17 Maintenance Page 17 19 Menu Icons Page 19 Date of Installation Affix Model Number Label Here 8016...

Page 2: ...7 15 v2 00 Page 1 of 20 ZIP HydroTap G4 User Guide Tap Operation Pages 2 6 LCD Screen Menu Pages 7 17 Maintenance Page 17 19 Menu Icons Page 19 Date of Installation Affix Model Number Label Here 8016...

Page 3: ...nds This is user adjustable To reset return the handle to the Off position and repeat the step The lever has to be manually returned to the Off position Elite Tap Touching any of the chilled buttons a...

Page 4: ...nds This is user adjustable To reset return the handle to the Off position and repeat the step The lever has to be manually returned to the Off position Elite Tap Touching any of the chilled buttons a...

Page 5: ...00 Page 3 of 20 Elite Tap The Elite tap uses touch sensitive controls in lieu of levers to dispense Chilled water Touching any of the chilled buttons allows the dispensing of chilled water Chilled Bu...

Page 6: ...00 Page 3 of 20 Elite Tap The Elite tap uses touch sensitive controls in lieu of levers to dispense Chilled water Touching any of the chilled buttons allows the dispensing of chilled water Chilled Bu...

Page 7: ...e rotary control is spring loaded in the anticlockwise direction and when released will return to the OFF position When rotated clockwise the tap operates in a Pot fill mode Water will flow from betwe...

Page 8: ...e rotary control is spring loaded in the anticlockwise direction and when released will return to the OFF position When rotated clockwise the tap operates in a Pot fill mode Water will flow from betwe...

Page 9: ...ll On all the time This indicates that the temperature of the chilled water is within the set temperature range Flashing slowly This indicates that the chilled water is not within the set temperature...

Page 10: ...ll On all the time This indicates that the temperature of the chilled water is within the set temperature range Flashing slowly This indicates that the chilled water is not within the set temperature...

Page 11: ...hen the filter is due for replacement and the LCD will show Filter Change Refer to Replacing the filter in section C of this document Filter Light Filter light 3 Filter light HydroTap Arc Cube Flashin...

Page 12: ...hen the filter is due for replacement and the LCD will show Filter Change Refer to Replacing the filter in section C of this document Filter Light Filter light 3 Filter light HydroTap Arc Cube Flashin...

Page 13: ...onds Zip HydroTap introduces a TOUCH screen for easy setup and operation adjustment See page 19 for icon details Other possible messages in status window Status Information Notes System Fault Product...

Page 14: ...onds Zip HydroTap introduces a TOUCH screen for easy setup and operation adjustment See page 19 for icon details Other possible messages in status window Status Information Notes System Fault Product...

Page 15: ...Information Installation Filter Flush Filter Reset Reset options Calibration options C Service Password protected D Security Enable Password Set Password Change Password E Communication Remote Monito...

Page 16: ...Information Installation Filter Flush Filter Reset Reset options Calibration options C Service Password protected D Security Enable Password Set Password Change Password E Communication Remote Monito...

Page 17: ...me button to return to the home screen 1 Press System Faults to check the fault information 2 Press button for the previous menu or press Home button to return to the home screen 1 Press MENU for main...

Page 18: ...me button to return to the home screen 1 Press System Faults to check the fault information 2 Press button for the previous menu or press Home button to return to the home screen 1 Press MENU for main...

Page 19: ...this is normal before pressing the Stop button Once the filter flush has finished press the Stop button to display the main menu Sub menu 1 Filter Flush 2 Filter Reset 3 Lux sensor calibration LCD Scr...

Page 20: ...this is normal before pressing the Stop button Once the filter flush has finished press the Stop button to display the main menu Sub menu 1 Filter Flush 2 Filter Reset 3 Lux sensor calibration LCD Scr...

Page 21: ...stall button 3 Press the Filter Reset button 4 To set the filter life or edit filter usage refer to section G Filter 3 Lux Sensor Calibration NOTE Conduct calibration under normal light conditions 1 P...

Page 22: ...stall button 3 Press the Filter Reset button 4 To set the filter life or edit filter usage refer to section G Filter 3 Lux Sensor Calibration NOTE Conduct calibration under normal light conditions 1 P...

Page 23: ...ange a password 1 Press the MENU button for main menu 2 Press the Security button 3 Press Change Password 4 Enter your old 4 digit password 5 Then enter your new 4 digit password You will need to ente...

Page 24: ...ange a password 1 Press the MENU button for main menu 2 Press the Security button 3 Press Change Password 4 Enter your old 4 digit password 5 Then enter your new 4 digit password You will need to ente...

Page 25: ...button for main menu 2 Press Setting button 3 Press Date Time button 4 Select 12 hour mode or 24 hour mode The selected mode will be displayed in dark grey colour with a tick box on the right 5 Press...

Page 26: ...button for main menu 2 Press Setting button 3 Press Date Time button 4 Select 12 hour mode or 24 hour mode The selected mode will be displayed in dark grey colour with a tick box on the right 5 Press...

Page 27: ...irst of these functions is reached i e Litres or months expired the filter warning light will be illuminated on the tap Either of these functions may be disabled See below Note Filter Life increases i...

Page 28: ...irst of these functions is reached i e Litres or months expired the filter warning light will be illuminated on the tap Either of these functions may be disabled See below Note Filter Life increases i...

Page 29: ...l show Sleep Mode Sleep Mode Light Level Time Delay State Boiler Chiller 2 Hours OFF N A 2 Hr OFF OFF OFF Lux Sensor OFF Dark N A OFF OFF OFF Lux or 2 Hr OFF Dark 2 Hr OFF OFF OFF Disable N A N A ON O...

Page 30: ...l show Sleep Mode Sleep Mode Light Level Time Delay State Boiler Chiller 2 Hours OFF N A 2 Hr OFF OFF OFF Lux Sensor OFF Dark N A OFF OFF OFF Lux or 2 Hr OFF Dark 2 Hr OFF OFF OFF Disable N A N A ON O...

Page 31: ...pt during OFF mode to dispense water will bring the unit out of energy mode The system will revert to the energy mode setting after 30 minutes of non use 1 Press the MENU button for main menu 2 Press...

Page 32: ...pt during OFF mode to dispense water will bring the unit out of energy mode The system will revert to the energy mode setting after 30 minutes of non use 1 Press the MENU button for main menu 2 Press...

Page 33: ...n to change and scroll using the up and down arrow Keys Air Inlet Filter The Zip HydroTap air filter is conveniently located on the outside of the condenser The filter screen is a sliding fit in the p...

Page 34: ...n to change and scroll using the up and down arrow Keys Air Inlet Filter The Zip HydroTap air filter is conveniently located on the outside of the condenser The filter screen is a sliding fit in the p...

Page 35: ...er flush stop cock a quick open and close will do Use the bucket to catch the discharge 3 Grasp filter cartridge depress the red lever at the top right of the filter and rotate the cartridge a quarter...

Page 36: ...er flush stop cock a quick open and close will do Use the bucket to catch the discharge 3 Grasp filter cartridge depress the red lever at the top right of the filter and rotate the cartridge a quarter...

Page 37: ...can be adjusted by litres and by days used See page 14 50 Chilled water temperature This icon indicates the set temperature of the chilled water inside the undersink unit CHILLED 6 10 C Cleaning Gener...

Page 38: ...can be adjusted by litres and by days used See page 14 50 Chilled water temperature This icon indicates the set temperature of the chilled water inside the undersink unit CHILLED 6 10 C Cleaning Gener...

Page 39: ...tents are in force and patent applications are pending Head Office Zip Heaters Aust Pty Ltd ABN 46 000 578 727 67 Allingham Street Condell Park NSW 2200 Postal Locked Bag 80 Bankstown 1885 Australia W...

Page 40: ...tents are in force and patent applications are pending Head Office Zip Heaters Aust Pty Ltd ABN 46 000 578 727 67 Allingham Street Condell Park NSW 2200 Postal Locked Bag 80 Bankstown 1885 Australia W...

Reviews: