Page 26 of 28 801912UK - Commercial Boiling, chilled and sparkling user manual - Sept 2016- v2.04
Leak Test
Stage 1
• Turn the gas off.
• Using soapy water applied with a
sponge, or with a brush, cover all of
the gas joints with a liberal amount
of suds.
Stage 2
• Turn the gas on.
• Inspect the joint for leaks.
• If any bubbles appear, the joint will need
to be resealed and tested again.
After replacing a cylinder or after making a gas connection,
perform a leak test
to check for gas leaks between regulator and cylinder, and
between regulator and braided hose.
Test for leaks at these two points