background image

801912UK - Commercial Boiling, chilled and sparkling user manual - Sept 2016- v2.04 

Page 9 of 28

All-in One HydroTap

®

G4

Tap functionality and 
operation

The top of the All-in-

One tap is operated in 

the same manner as a 

Classic HydroTap

®

G4. The 

two levers are used for 

dispensing boiling, chilled 

and sparkling water. The 

safety lock also operating 

in the same manner as the 

Classic HydroTap

®

G4.

The mixer tap lever is 

operated as a conventional 

‘flick mixer’. The hot direction 

is marked with a red dot and 

the cold direction with a blue dot, for dispensing cold to warm water. 
Moving the lever away from the tap will increase the flow rate and towards 

the tap will decrease the flow rate. 
When the lever is moved in the direction of the blue dot, the temperature is 

decreased and when moved in the direction of the red dot, the temperature 

is increased. The final temperature will be dependant on the temperature 

of the incoming cold water. The spout may be swivelled, left or right, for 

convenience.

Classic , Arc and Cube mixer taps

Tap functionality and operation

Classic, Arc and Cube mixer taps operate in the same manner as the All in One mixer 

tap, detailed above.

Summary of Contents for 801912UK

Page 1: ...801912UK Commercial Boiling chilled and sparkling user manual Sept 2016 v2 04 Page 1 of 28 ZIP HydroTap G4 User Manual Affix model number label here 801912UK...

Page 2: ...sure the touch surface is dry as moisture may interfere with the sensor touch control The safety lock can be controlled from either the tap or from the touch screen display See page 22 Filter light Bo...

Page 3: ...Touching the red BOILING button allows the dispensing of boiling water To dispense boiling water with the safety lock on Place a finger on the safety lock then touch the red BOILING button keeping bot...

Page 4: ...indicates that the boiling water is below the set dispense temperature Wait for the light to stop flashing before dispensing water The light will typically flash after switching on or coming out of sl...

Page 5: ...e the tap safety lock see page 22 For hot isolation see page 22 To dispense boiling water with the safety lock off Press the red BOILING lever to dispense boiling water Pulling forward the red BOILING...

Page 6: ...neutral position Safety sensor calibration Light intensity varies from site to site therefore it is recommended that a recalibration be performed at the time of the installation All direct sunlight m...

Page 7: ...quickly warning light When the indicator light flashes quickly and continuously a system fault has occurred Check for details on the faults screen see page 12 If unable to rectify call a qualified se...

Page 8: ...trol while the three red illuminated lights are flashing While dispensing boiling water all three red illuminated lights will continue to flash To dispense chilled water Rotate the control when the in...

Page 9: ...d with a red dot and the cold direction with a blue dot for dispensing cold to warm water Moving the lever away from the tap will increase the flow rate and towards the tap will decrease the flow rate...

Page 10: ...iling water or hot water is not available Refer to section G Energy modes Change Filter External Internal filter needs to be replaced Refer to section C Installation System Off System off in off mode...

Page 11: ...llation Filter flush Filter reset Boiling calibration Booster CO2 Purge Lux sensor calibration Start Stop Internal External Calibration options Enable Disable C Service Password protected D Security E...

Page 12: ...menu or press HOME button to return to the home screen Press Filter Log to check the filter resets Press button for the previous menu or press HOME button to return to the home screen Press the MENU...

Page 13: ...e of the cartridge is a flush line approx 600mm long and the flush line stop cock Place the free end of the flush line into the bucket or container not supplied Press MENU button for main menu Press t...

Page 14: ...he MENU button for main menu Press the Install button Press the Boost button In the next screen press button A to enable the booster dispense boiling water for 30 seconds and check the insulated outle...

Page 15: ...o stop flowing through the unit Wait a further 10 seconds after the water has stopped running During this time you will hear the CO2 gas running through the tap The purge will stop automatically 6 Lux...

Page 16: ...Zip on 0345 6 005 005 for assistance service spare parts or enquiries E Security The Zip HydroTap G4 allows the appliance coordinator to set up a password to protect against users changing the prefer...

Page 17: ...nter your 4 digit password to access the WiFi set up Follow the set up instructions in the ZipAssist installation manual WiFi Setup Zip BC Sparkling 15 11 Tue 26 July 2016 Cloud server not registered...

Page 18: ...or 24 HOUR mode by pressing the square button The selected mode will be displayed in dark grey colour with a tick box on the right Press NEXT button to set time Set Date Time Press the MENU button for...

Page 19: ...maximum of 10000 litres Factory set at 6000 litres To edit the filter usage This function is to reset the filter change display after a filter has reached the end of its life see page 23 Filter maint...

Page 20: ...Hours OFF N A 2 Hr OFF OFF OFF Lux Sensor 680 C Dark N A Sleep 680 C ON Lux Sensor OFF Dark N A OFF OFF OFF Lux Sensor or 2 Hr 680 C Dark 2 Hr Sleep 680 C ON Lux Sensor or 2 Hr OFF Dark 2 Hr OFF OFF O...

Page 21: ...off at a specific time To activate On Off mode Press the MENU button for main menu Press the Settings button Enter your 4 digit password and press Enter Press the Energy Modes button Press the On Off...

Page 22: ...s equipped with a safety mode that allows for additional safety protection if needed Hot isolation To allow safety changes select YES on the safety settings screen To activate press button to disable...

Page 23: ...HydroTap G4 notifies when filter replacement is due If you notice one of the following you will need to change the filter The white change filter light will flash and remain so until reset The filter...

Page 24: ...a quarter turn anticlockwise until the cartridge comes to complete stop and is locked into position with the front label facing forward Initiate the filter flush programme by scrolling through the me...

Page 25: ...raided hose is removed from the regulator be careful not to lose the small plastic sealing olive located inside the end of the hose Screw the regulator and hose assembly clockwise onto the new cylinde...

Page 26: ...r all of the gas joints with a liberal amount of suds Stage 2 Turn the gas on Inspect the joint for leaks If any bubbles appear the joint will need to be resealed and tested again After replacing a cy...

Page 27: ...displayed no power is being supplied to the heating element See page 20 for Energy Mode options Filter use This icon displays the filter usage remaining from 100 new filter to 0 end of life When it r...

Page 28: ...ticides near the Command CentreTM Contact details Website www zipwater com uk Email sales zipindustries co uk Facsimile 01362 692 448 Telephone 0345 6 005 005 Head Office Zip Water UK 14 Bertie Ward W...

Reviews: