Page 7 of 12
Zip CH103, CH104 - Installation & operating instructions - 82127UK - June 2015 v1.04
CH104 Wall Fountain installation instructions
Zip Wall Fountain should only be installed by a competent installer in accordance
with local water authority by-laws and these instructions.
Zip Wall Fountain is designed to be recess mounted within a wall. The bottom
should sit on a supporting flat and level plinth at least 100mm above finished floor
level. The plinth height determines the final height of the dispensing tap, as the tap
base is fixed at 915mm above the bottom of the unit.
Check that there is enough free space within the wall to allow for completely
recessing the Wall Fountain. The top half recesses 270mm and the bottom half
requires a depth of 350mm to allow for the chiller unit and to provide adequate
ventilation space.
Wall cut-out
The cut-out dimensions are 1630mm high by 555mm wide.
The Wall Fountain has a 40mm flange on both sides and the top, designed to cover
gaps or rough edges to the recessed aperture. The bottom front edge has no flange,
so the plinth must be finished level and neat as it will always remain visible.
Ensure the cut-out is square and even to allow the Wall Fountain to fit without
distortion.
635
555
1670
915
355
385
1630
28
300
270
13
leave
space
for
chiller
40
40
257