background image

5

Instructions for user - CEX9-U - 801041 - November 2018 v1.00 Art.no:

 9120-25688

2. Overview

When ordering spare parts, please always specify the appliance model and serial number.

Parts in 

Bold Type

 are available as 

Spare Parts

. Other parts are available on request

Pos.

 Part.-No.  Description

1

Grommet

2

 

Connecting terminal

99394

Flow sensor 

99385

Non-return valve

5

99398 

PCB CEX9

6

99418 

CEX control panel

Inlet pipe

 

CEX-U cover

Pos. 

Part.-No.  Description

9

 

Inlet filter

10

 

Connection piece 1/2“

11 

 

Safety thermal cut-out

12 

99400

Thermal sensor set

13 

Heating element incl. SDB

14

Bottom part

15

99397

Screws and dowels

12

13

14

15

6

7

8

5

4

3

2

1

10

11

9

Summary of Contents for CLAGE CEX9-U

Page 1: ...taneous Hot Water Electronically controlled instantaneous water heater CEX9 U 27910 50 C model Instructions for the user For 50 C models the appliance delivers water not exceeding 50 C in accordance w...

Page 2: ...chnical data 6 4 Dimensions 7 5 Description of the appliance 7 6 Operation 8 Temperature setting 8 Programme buttons 8 Reset to factory setting 9 How to save energy 9 ECO mode 9 Power limit 9 Top up h...

Page 3: ...especially by children and may cause a feeling of burning Please note that the fittings and taps may be very hot when the appliance has been in use for some time The appliance is only suitable for do...

Page 4: ...o other fittings or appliances which decrease the water flow to the shower may be installed age by an authorised technician in order to avoid any hazards For appliances with direct connection an all p...

Page 5: ...parts are available on request Pos Part No Description 1 Grommet 2 Connecting terminal 3 99394 Flow sensor 4 99385 Non return valve 5 99398 PCB CEX9 6 99418 CEX control panel 7 Inlet pipe 8 CEX U cov...

Page 6: ...tem Bare wire heating system IES Required spec water resistance 15 C Spec electrical conductivity 1100 cm 90 9 mS m Inlet temperature 70 C Flow rate to switch on max flow rate 2 0 5 0l min 2 Pressure...

Page 7: ...trol regulates the power consumption depending on the selected outlet temperature the respective inlet tempera ture and the flow rate thus reaching the set temperature exactly to the degree and keepin...

Page 8: ...appliance automatically switches off Set temperature 1 1 C 1 C Select preset temperature A1 A2 B1 B2 Store temperature 2 Press 3 sec Display of new value e g 43 C Set required temperature e g 43 C 4...

Page 9: ...e of the electronic cir cuitry with the result that temperature constancy is no longer guaranteed How to save energy The symbol shows that the appliance works in an energy saving mode i e the momentar...

Page 10: ...rtently running dry Nevertheless the appliance must be vented before using it for the first time Each time the appliance is emptied e g after work on the plumbing system if there is a risk of frost or...

Page 11: ...al display does light up Safety thermal cut out tripped Contact customer service Display flashes error mes sage Er Control system has switched off Switch fuse off and on If Er still flashes contact cu...

Page 12: ...have been modified and may not be true representations of the finished goods 1 3 2 1 2 1 1 C 1 C A1 A2 B1 B2 2 4 3 1 1 0 5 C 0 5 C 3 1 2 2 8 4 7 5 3 6 9 1 Arrow key down Arrow key up Programme button...

Reviews: