WARNINGS AND PRECAUTIONS

!

This manual contains important safety and installation instructions for the Zip Econoboil.

Please read all warnings, installation requirements and installation instructions before installing any 

Zip Econoboil. This system must be installed in accordance with water supply byelaws, current IEE 

regulations and relevant local authority byelaws.

Warnings

• 

  The Zip Econoboil

 

must be earthed. The resistance of the earth connection from each exposed metal part 

must be less than 1

Ω

.

• 

All installation and service work must be completed by trained and suitably qualified tradespeople. Faulty 

operation due to unqualified persons working on this product, or any other Zip product may void warranty 

coverage.

•  Never attempt to install a Zip Econoboil instant boiling water heater without reading all of the applicable 

instructions.

•  Do not remove the cover of the Econoboil under any circumstances without first isolating it from the power 

supply.

•  In hard water areas mineral scale accumulation in the boiling chamber of the Zip Econoboil may become a 

problem, consideration should be given to the maintenance required. A suitable form of water treatment may 

be necessary.

•  The Zip Econoboil instant boiling water heater is not intended for use by young children or infirm people 

without supervision. 

•  Young children should be prevented from having access to ensure that they are not able to use or play with 

the Econoboil.  

•  Do not use strong, corrosive or abrasive cleaners to clean the case of the Econoboil.
•  The ambient temperatures this Econoboil must operate within are 5ºC - 50ºC.
•  The Econoboil is intended only for indoor use and should never be installed outdoors or be exposed to the 

elements of nature.

•  The Econoboil must not be positioned in an area that may be cleaned by a water jet. The Econoboil must not 

be cleaned by a water jet.

•  Frost protection: If the Econoboil is located where ambient air temperature could fall below 5ºC when the 

Econoboil is not in use, do not turn off the Econoboil electrically. This safeguard does not offer the same 

protection to the connecting pipework and fittings.

• 

As the installer, it is your responsibility to supply (if necessary) and install all valves as required by local 

regulations and relevant standards.

• 

The Econoboil is rated for 230V 50Hz AC operation.

• 

Due to the process of continuous improvement, Zip reserves the right to change details mentioned in this 

manual, without notice.

• 

Visit www.zipwater.co.uk to ensure you have the latest copy of this document.

Summary of Contents for Econoboil 305542

Page 1: ...anual 804544UKV2 03 Oct 2018 Zip Econoboil Technical support Tel 0345 6 005 005 Email service zipindustries co uk www zipwater co uk Installation instructions user manual Zip Econoboil On wall boiling...

Page 2: ...ction and venting Plumbing connections 7 Venting 7 Electrical connections 8 Step 4 Assembly Assembly 8 Step 5 Commission the Econoboil Earth continuity verification 9 Turn the mains power and water on...

Page 3: ...nsideration should be given to the maintenance required A suitable form of water treatment may be necessary The Zip Econoboil instant boiling water heater is not intended for use by young children or...

Page 4: ...rvised to ensure that they do not play with the Econoboil The Econoboil is intended to be used in commercial applications Qualifications If the power cable is damaged it must be repaired only by a qua...

Page 5: ...ket or double pole isolation switch correctly rated for the appliance is required The Econoboil must be connected in accordance with IEE regulations See Technical specification page 6 for power rating...

Page 6: ...board or drip tray Position the base of the tap nozzle to be not less than 280mm nominally 360mm above the draining board height should be increased only if essential for filling larger vessels Provi...

Page 7: ...isolated from the mains water supply for servicing Water pressure requirements See Technical specification page 6 Venting The Econoboil is an open vented water heater and as such it is essential to pr...

Page 8: ...e page 9 Strain relief bush Terminal block Rear access Step 4 Assembly Without the cover on turn the water on to check for any leaks These should become apparent within a short period of time If all i...

Page 9: ...r may be boiling Verify that in every instance the electrical resistance does not exceed 1 ohm Warning This appliance must be earthed Turn water supply ON Water will flow into the Econoboil check conn...

Page 10: ...l valve assy airlock in transfer tube Check water supply valve Contact Zip authorised agent Water not boiling No power Faulty thermostat faulty element faulty cut out Check power supply Contact Zip au...

Page 11: ...ntly pull the top of the tap forward Boiling water will flow until the tap handle is released This operation gives fingertip flow control for safe filling of cups and mugs To fill larger vessels such...

Page 12: ...o uk www zipwater co uk Wall mounting dimension 37 3 0L 198 52 5 0L 38 3 0L 52 5 0L 19 395 3 0L 429 5 0L 37 76 273 3 0L 302 5 0L 56 COLD INLET BOILING WATER VENT 25 40 70 Positioning pin 6 External pl...

Page 13: ...0081 Thermostat 9 94752 Loom Ther Overload 10 94753 Wire Brown 140mm 6 3QC x 1sqmm 11 Not available 12 94454 Cistern Tank 13 94755 Ball Valve Assy 14 94456 Cistern Gasket 15 94457 Cistern Lid 16 SP931...

Page 14: ...ions user manual 804544UKV2 03 Oct 2018 Zip Econoboil Technical support Tel 0345 6 005 005 Email service zipindustries co uk www zipwater co uk Spare parts 1 3 4 6 7 5 2 10 8 23 22 9 19 17 18 15 14 13...

Page 15: ...of separately to any other household waste Within each of the European Union member countries provisions have been made for collection and recycling of unwanted electrical and electronic equipment In...

Page 16: ...04544UKV2 03 Oct 2018 Zip Econoboil Technical support Tel 0345 6 005 005 Email service zipindustries co uk www zipwater co uk ZipWater UK 14 BertieWardWay Dereham Norfolk NR19 1TE 0345 6 005 005 sales...

Reviews: