Page 6 of 16
Zip Econoboil - Installation & Operating Instructions - 81441 - July 2015 v1.03
Before fitting outer case, turn the water on to check for any leaks. If there are any
leaks re-visit plumbing instructions. If all is dry then isolate water.
d) Connect timer
Ensure the on-wall boiling water unit has been disconnected / isolated
from the electrical power supply.
Remove battery isolation strip (if strip is present) as per Fig.1.
Connect the wiring between the timer and Econoboil as per Fig.2 and Fig.3.
Step 4 – Assembling
Fit the cover and screws, then fit the red escutcheon over the outlet tube and
apply PTFE tape to the threaded portion of the outlet tube, if not already applied.
See Fig.4.
Screw the tap assembly clockwise onto the outlet tube until it touches the
escutcheon without pressure, see Fig.5. Continue to turn the tap one full rotation
maximum until the handle is fully vertical.
Step 5 – Commissioning
Check previous steps. Turn water supply ON. Water is now flowing into heater, check
connections for leaks. Wait approximately 5 minutes and check outlet tap for water.
This is acheived by pulling the tap handle forward.
Power is only to be turned on when water is available from this outlet.
Check timer settings are in the ON mode as per instructions on page 7.
Turn power ON. After a short period, boiling water will be available and will be
maintained close to boiling point thereafter. Initial heating periods are shown in the
table below.
Installation Procedures
Continued
Inlet water Temperature
15ºC
10ºC
3 Litre models
16 minutes
17 minutes
5.0 Litre models
16 minutes
17 minutes
7.5 Litre models
23 minutes
24 minutes
Electrical
Timer
wiring
Econoboil
wiring
Fig.4
Fig.5
Fig.2
Fig.3
Fig.1
Isolation
strip(if fi tted)