background image

2

INSTALLATION INSTRUCTIONS & USER MANUAL 

T210012 V1.00 FEB 2018 -ZIP HYDROCHILL 10

TECHNICAL SUPPORT

 TEL: 0345 6 005 005 EMAIL: SERVICE@ZIPINDUSTRIES .CO.UK   

WWW.ZIPWATER.CO.UK

PRECAUTIONS AND GENERAL RECOMMENDATIONS

TABLE OF CONTENTS

Precautions and recommendations ....................................................................... 2

Before installing the HydroChill  ............................................................................ 3

Product approvals  & product description .............................................................. 4

Technical features  ................................................................................................ 5

Technical data  .................................................................................................... 10

Installation ........................................................................................................... 11

General CO2 cylinder safety guidelines  ............................................................. 17

Filtration (inc.Ultra violet (UV) filtration) ............................................................... 18

Sanitisation .......................................................................................................... 20

Maintenance ........................................................................................................ 21

Safeguarding the environment ............................................................................ 22

Warranty .............................................................................................................. 23

Contact details ..................................................................................................... 24

• Appliance for internal use only.

 Place the unit away from water  

jets.

• Always connect the water cooler 

to a water main that supplies 

wholesome drinking water only.

• Before each installation, the unit 

must be sanitized by an authorized technician.

•  After installation, ensure that the unit is not resting on the power cable.

• 

Check that the unit is level and that it is resting on a surface with sufficient 

load bearing capacity, in an environment that is suitable for its dimensions 

and its use.

•  Before any maintenance or cleaning operation is carried out, remove the plug 

from the socket or disconnect the power supply.

•  Ensure that the product is not sited close to sources of heat.

•  To guarantee adequate ventilation, leave at least 10 cm of space around the 

unit.

•  Install the product in a clean, dry, well-ventilated environment. The product 

is designed to function in environments with a temperature range of between 

5°C and 32°C - Climate Class N.

• 

Take care not to damage the cooling fluid circuit: it is filled with R290, which

 

is a highly flammable gas. It is essential to ensure that the tubes of the 

refrigerant circuit are not damaged.

•  Ensure that it is possible to disconnect the power supply either by removing 

the plug or via a two-pole circuit-breaker, with a contact separation of at least 

!

Summary of Contents for HYDROCHILL HC10 Series

Page 1: ...T210012 V1 00 FEB 2018 ZIP HYDROCHILL 10 TECHNICAL SUPPORT TEL 0345 6 005 005 EMAIL SERVICE ZIPINDUSTRIES CO UK WWW ZIPWATER CO UK ZIP HYDROCHILL INSTALLATION INSTRUCTIONS USER MANUAL MODEL NUMBER HC...

Page 2: ...allation ensure that the unit is not resting on the power cable Check that the unit is level and that it is resting on a surface with sufficient load bearing capacity in an environment that is suitabl...

Page 3: ...se extension leads or adapters This appliance is intended to be used by persons including children aged from 8 years with reduced physical sensory or mental capabilities or lack of experience and know...

Page 4: ...rcuit PRODUCT DESCRIPTION Compact powerful and entirely made of stainless steel HydroChill HC10 is the smallest cooler of the range perfect for your home and office with professional performance The m...

Page 5: ...ront of product Explanation of HydroChill range product code HC HydroChill Range Product group 10 range 20 range 50 range C Chilled only Chilled sparkling T Dispensing tap IT Buttons BIT Bridge XX HC...

Page 6: ...45 6 005 005 EMAIL SERVICE ZIPINDUSTRIES CO UK WWW ZIPWATER CO UK TECHNICAL FEATURES REAR Slide cover IEC outlet power cable Power button Drinking water inlet pipe joint 5 16 8mm CO2 inlet pipe joint...

Page 7: ...oHS COMPLIANT 2011 65 EU Wholesome water only GAS g situated on the back of product Class N Made in Italy Serial no PRODUCT 230V 50 Hz KW A RoHS COMPLIANT 2011 65 EU wholesome water only GAS g Product...

Page 8: ...10 TECHNICAL SUPPORT TEL 0345 6 005 005 EMAIL SERVICE ZIPINDUSTRIES CO UK WWW ZIPWATER CO UK TECHNICAL FEATURES DISPENSING BUTTONS Filtered chilled water Filtered sparkling water model specific Filter...

Page 9: ...1 00 FEB 2018 ZIP HYDROCHILL 10 TECHNICAL SUPPORT TEL 0345 6 005 005 EMAIL SERVICE ZIPINDUSTRIES CO UK WWW ZIPWATER CO UK TECHNICAL FEATURES 30 model 45 model Dimensions sparkling model shown for ref...

Page 10: ...essional membrane carbonation pump Condensation Ventilated Adjustable Thermostat Yes Refrigerant gas R290 Supply 230 V 50 Hz Compressor power 1 8 HP 1 5 HP Watt 230 W 1 A 300 W 1 3 A Inlet water Pipe...

Page 11: ...u have unpacked the unit ensure that it is not damaged You must inform the reseller about any damages as soon as possible after delivery If the unit has been shipped horizontally or at an angle it wil...

Page 12: ...t The unit must be handled by two people Site the unit away from sources of heat Do not place on inclined surfaces Leave at least 10cm around the unit to allow for ventilation Sanitise the product as...

Page 13: ...EMAIL SERVICE ZIPINDUSTRIES CO UK WWW ZIPWATER CO UK INSTALLATION Water supply connection detail assembled Incoming cold mains water supply Isolation valve not supplied Water block 15mm to 1 2 couple...

Page 14: ...excess of 3 5 l min is recommended Connect incoming water tube 1 above to the drinking water main ideally with a tap upstream of the HydroChill Connect the drip tray provided closed 2 to a drainage p...

Page 15: ...rn the unit on by selecting the I position on the main on off rocker switch 2 The compressor and fan are now activated On the sparkling models the carbonator pump is also activated Press the Sparkling...

Page 16: ...90 food grade carbon dioxide CO2 cylinder Attach the regulator CO2 pipe to the cylinder valve Insert the CO2 inlet tube from the cylinder into the fitting 1 Be sure to remove any air in the hydraulic...

Page 17: ...cylinders must be handled with care It is essential to avoid Clashes with other cylinders or surfaces dropping the cylinders or subjecting them to mechanical stress All of the above may compromise the...

Page 18: ...e sanitary cap write today s date where shown on the label Avoid touching the filter o rings and filter opening as this may cause bacterial contamination of the cartridge Moisten the o rings with wate...

Page 19: ...terilizing UV filter Alongside the carbon filter it is also possible to have your water cooler fitted with a UV C 254 nm sterilizing filter on the dispensing point The UV C light emitted by the specia...

Page 20: ...CO UK SANITISATION General guidelines The HydroChill should be sanitized at first installation or When the hydraulic components are being replaced or When the filter is being changed or in any case a...

Page 21: ...s or excessively acidic solvents that can ruin the surface of the steel Cleaning the drip tray When it is necessary to clean the drip tray use a diluted lime scale cleaner citric acid or similar The d...

Page 22: ...ose of this product correctly Please contact Zip Customer Service for advice on 0345 6 005 005 End of life disposal Packaging materials The packaging materials are 100 recyclable Please follow the loc...

Page 23: ...or the cost of removal cartage and re installation of any component of the appliance if it needs to be returned for repair to Zip or its Distributor This warranty does not cover damage resulting from...

Page 24: ...0012 V1 00 FEB 2018 ZIP HYDROCHILL 10 TECHNICAL SUPPORT TEL 0345 6 005 005 EMAIL SERVICE ZIPINDUSTRIES CO UK WWW ZIPWATER CO UK Zip Water UK 14 Bertie Ward Way Dereham Norfolk NR19 1TE 0345 6 005 005...

Reviews: