background image

33

805812 v1.04 05.20 HydroChill Install Instructions

Performance Data Sheet

Zi

p

 GlobalPlus Water Filter ZGP 65S

Part number 92323

These systems have been tested according to NSF/ANSI Standard 42 and/ or AS/NZS 4348 for the reduction of the substances listed below.

 

The concentration of the indicated substances in water entering the system was reduced to a concentration less than or equal to the permissible 

limit for water leaving the system as specified in NSF/ANSI Standard 42 and/ or AS/NZS 4348

Contaminant Reduction

Avg. Influent

NSF/ANSI Specified Challenge 

Concentration

Avg. % 

Reduction

Avg. 

Product Water 

Concentration

NSF Reduction 

Requirements

NSF Test 

Report

Chlorine taste and odour

2.0 mg/L

2.0 mg/L ± 10%

96.6

0.07 mg/L

≥ 50%

J-00089365

Application guidelines / water supply parameters

Capacity

132,489 litres

Service flow

12.6 lpm

Water pressure

172-862 kPa (25-125 psi)

Water temperature

4.4 – 38 ºC 

Testing Condition:

 pH: 7+/-1

Temp: 20+/-5 Celsius

Pressure: 600 kPa +/- 100 kPa
Note that while the testing was performed under standard laboratory 

conditions, actual performance may vary. Systems must be installed 

and operated in accordance with manufacturer’s recommended 

procedures and guidelines. Failure to dosomay void warranty. See 

Warranty Card for Details. 

Caution:

 This filter system or cartridge is 

designed to be installed on the Cold water line. Do not install on Hot 

water line.

Warning:

 AS3497:1998 requires dual backflow prevention and 

certified pressure control device to be installed prior to filter system(s) 

that are plumbed into mains water supply. Failure to do so will not 

only void all warranty(s) on the filter system(s), but will put the home 

at risk of flooding in the event of damaged appliances during pressure 

surges.

Caution: 

Do not use with water that is microbiologically unsafe or 

of unknown quality without adequate disinfection before or after 

the system. Systems certified for cyst reduction may be used on 

disinfected water that may contain filterable cysts.

To reduce the risk associated with property damage due to water 

leakage:
• Read and follow instructions before installation and use of this

system

• Installation and use must comply with existing state or local

plumbing codes

• Protect filter from freezing. Drain filter when room temperature

drops below 4.4

o

C

• Contact plumbing professional if you are uncertain how to check

your water pressure

• Do not install where water hammer conditions may occur. If water 

hammer conditions exist you must install a water hammer arrester.

Contact a plumbing professional if you are uncertain how to check

for this condition

• Install on cold water lines only. Do not install on hot water supply 

lines. The maximum operating water temperature of this filter 

system is 38⁰C

• The disposable filter cartridge must be replaced every 12 months

or at the specified service cycle, whichever comes first

• Do not install near water pipes which will be in path of a drilling

tool when selecting the position to mount the bracket

• Mount filter in such a position as to prevent it from being struck by 

other items used in the area of installation (waste baskets, etc.)

Note:

 Zi

p

 filter systems are designed for ease of installation. 

However, post-installation inspections are highly recommended. 

Check for leaks immediately after installation and once again after 

24 

hours. If leaks are detected, turn off water supply, drain water and 

inspect the leaks. If problem persists, contact the installer / plumber 

for rectification.

It is essential that operational, maintenance and filter replacement 

requirements be carried out for this product to perform as advertised.

Flush new cartridge for at least 2 minutes to remove trapped air 

bubbles.

If left unused for more than 24 hours, flush cartridge for 2 minutes 

before use.

Treatment and Tests – Table C1

This appliance meets the domestic water treatment appliance Standards AS/NZS 3497 and AS/NZS 4348 for the following water treatment process.

Class

Treatment Type

Function

Pass

I

Microbiological Status Will stop 

bacteria increasing, but will n/a 

Bacteriostatic

Will stop bacteria increasing, but will not remove them 

unless II (a) is ticked

n/a

II

Microbiological Treatment

II (a)

Bacteria Removal

Will remove inactive bacteria

n/a

II (b)

Virus Removal

Will remove inactive virus

n/a

II (c)

Protozoa Removal

n/a

III

Turbidity & Particulate Reduction

Will reduce cloudiness

n/a

IV

Taste & Odour Reduction

Will reduce taste and odour

4

V

Chemical Treatment

Will decrease chlorine compounds

4

Note: the use of this appliance may increase the bacterial content of the water unless supplementary treatment is provided.

Legend:    

4

 = Pass Test    N/A = Not applicable

Zip GlobalPlus Water Filter ZGP 65S

Part number 92323

Maintenance

Summary of Contents for HydroChill Te-Mix Aqua 15

Page 1: ...1 805812v1 0405 20HydroChillInstallInstructions Installation instructions usermanual Zip HydroChill InstantChilledandSparklingwater Models HCF90 HCF120 HCF200 HCS90 HCS120 HCS200 AFFIXPRODUCTLABELHERE...

Page 2: ...ion instructions 16 Step 1 Install the Tap Font 16 Step 2 Install Chiller 17 Step 3 Connect Carbon Dioxide CO2 Cylinder 20 Step 4 Connect hoses 22 Step 4 Commissioning 24 Operation 25 Maintenance 26 D...

Page 3: ...dren aged from 8 years and above and persons with reduced physical sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use...

Page 4: ...ng children with reduced physical or sensory capacities or with a lack of experience and knowledge unless under supervision and with the instructions of someone responsible for their safety Make sure...

Page 5: ...with a filter to dispense Still water at room temperature Still chilled water Sparkling chilled water The water is carried through thermally insulated tubes from the chiller to the font The insulating...

Page 6: ...ct to the outlet taps HCF Chilled Filtered 2 tap fonts include 4 hoses 2 clear for drinking water and 2 black for recirculation HCS Sparkling 3 tap fonts include 5 hoses 3 clear for drinking water 2 b...

Page 7: ...13 805301 CO2 Regulator 1 14 805955 3 8 x 3 8 Straight Adaptor not shown 2 Item Part No Description QTY 1 805587 Armaflex 2 m 2 805467 JG 3 8 Hose Natural White 5 m 805469 JG 3 8 Hose Blue 5 m 3 80558...

Page 8: ...ification Te Mix Aqua 15 L HCS90 HCF90 add 25mm for roller feet 40mm for handles Te Mix Aqua 25 L HCS120 HCF120 add 25mm for roller feet 40mm for handles Te Mix Aqua 50 L HCS200 HCF200 add 25mm for ro...

Page 9: ...21 Cold water coil AISI 304 Stainless Steel Refrigerant R134a Compressor cooling power W at ambient 32 C 400 513 905 Carbonation pump L h 200 200 300 Carbonator volume cc 1100 1100 2000 Carbonation p...

Page 10: ...10 805812v1 0405 20HydroChillInstallInstructions Technical specification Te Mix Aqua 15 HCS90 HCF90...

Page 11: ...NEL 9 CARBONATION PUMP order code 2311361 10 CARBONATION PUMP MOTOR 11 FAN UNIT 12 CONDENSER 13 DEHYDRATOR FILTER 14 OVERFLOW DRAINAGE 15 DRAINAGE POINT FOR EMPTYING TANK 16 ON OFF LIGHT SWITCH 17 THE...

Page 12: ...12 805812v1 0405 20HydroChillInstallInstructions Technical specification Te Mix Aqua 25 50L HCF 120 HCF 200 HCS 120 HCS 200...

Page 13: ...EVAPORATOR 7 INSULATING TANK 8 SIDE PANEL 9 FAN AND FAN MOTOR 10 DEHYDRATOR FILTER 11 CONDENSER 12 LEVEL CONTROL UNIT 13 CARBONATION PUMP MOTOR 14 CARBONATION PUMP 15 RECIRCULATION PUMP SOCKET 16 THER...

Page 14: ...k will not be obstructed when the under counter chiller is installed D A 350 kPa 3 5 bar pressure limiting valve supplied must be fitted E All plumbing must comply with the relevant parts of AS NZS 35...

Page 15: ...ip tray supplied separately no cut out required Drip tray options Zip Water Pty Ltd BKL001 HydroChill HCF HCS AU NZ v1 11 04 20 100 200 min clearance 200 min clearance 333 425 491 610 650 745 900 900...

Page 16: ...ugh the 50 mm hole Fit the rubber base seal supplied to the base of the tap font to seal it on the benchtop Secure the font from under the bench with the washer and nut Option Recessed drip tray part...

Page 17: ...tall the kickboard vent grille for external air intake Install the fan at the top of the cupboard to extract hot air out of the cupboard requires additional electrical power outlet Cut out in the cabi...

Page 18: ...Unpack the filter cartridge and remove the sanitary cap Avoid touching the filter O rings or filter opening as this may cause bacterial contamination of the cartridge 5 Write today s date where shown...

Page 19: ...l the water tank Remove the upper cover B by loosening the fixing screw Fill the tank with clean water until the level is about 2 cm 1 inch below the hole C of the overflow connector Ensure no foreign...

Page 20: ...bly fit with sufficient clearances before securing the bracket Connect the pressure regulator The pressure regulator is supplied with interchangeable colour coded pressure relief valves The GREY colou...

Page 21: ...arbonation Ensure the inlet water pressure is below 300kPa 3 bar 45 psi To improve carbonation set a lower temperature on the chiller machine Test for gas leaks IMPORTANT After replacing a gas cylinde...

Page 22: ...hiller Step 4 Connect hoses Installation Tap 1 Fit John Guest fittings to outlet connections Chilled Sparkling and Recirculation 2 4 Once tap is installed fit Sparkling Chilled Ambient lines with 3 8...

Page 23: ...t Armaflex to fit and wrap hoses to tap 7 Tightly wrap split Armaflex for condensation control 8 Wrap but expose the stop valves up to the Tap so adjustment can be made if necessary Mark the stop valv...

Page 24: ...lation for the water to reach optimum chilled temperature If the water circuit freezes turn power OFF for at least 12 hours to defrost Adjust the thermostat anti clockwise HCS Sparkling models Adjust...

Page 25: ...upply and the valve of the CO2 bottle Protect from heat and bad weather Keep covered to protect from dust and or splashes Sanitise the system and flush the filter before resuming operation Moving the...

Page 26: ...etergent To prevent damage do not use abrasive materials solvents alcohol etc Do not clean with water jets Clean the dispensing nozzles with a diluted hydrogen peroxide solution or sanitisation wipes...

Page 27: ...roughly with clean water to make sure that all traces of sanitising agent have been eliminated completely Sanitisation procedure Switch off the machine and dispense through the taps until the system i...

Page 28: ...ime 1 Disconnect power and water 2 Remove the upper cover 3 If ice has formed allow 12 hours for the ice to melt 4 Refer to the drainage system A 5 Loosen the fixing screw B 6 Hold the upper end of th...

Page 29: ...rt the tube in the lower slot of the plastic clip G 10 Turn the tube and insert it in the front of the upper slot H Slide the tube so you can insert the plastic clip in its seat 11 Press the clip and...

Page 30: ...ve Do not adjust the regulator Inspect carbonator liquid check valve every 12 months The carbonator liquid check valve prevents carbonated water from flowing backwards into the potable water supply In...

Page 31: ...npack the replacement cartridge and write today s date where shown on the label 6 Remove the sanitary cap Avoid touching the filter O rings or filter opening as this may cause bacterial contamination...

Page 32: ...off water supply and the valve of the CO2 bottle Protect the chiller from heat dust and water splashes If the machine needs to be moved stored or shipped the system must be sanitised All water must be...

Page 33: ...when room temperature drops below 4 4o C Contact plumbing professional if you are uncertain how to check your water pressure Do not install where water hammer conditions may occur If water hammer cond...

Page 34: ...e closed Open the water valve Water supply hose crushed or obstructed Check and correct the path of the hose No electricity supply Check the power switch electrical cable and connections Water is froz...

Page 35: ...corrosive spray or abrasive cleaners Clean the case with a soft cloth or brush and mild soap and water Clean the tap with a damp cloth In order to help preserve our environment we ask that you dispos...

Page 36: ...AP 1800 947 827 Zip products described in this publication are manufactured under one or more patents and further patent applications are pending As Zip policy is one of continuous product improvement...

Reviews: