Hydro Tap Installation and Operating Instructions - 89026UK - June 2009 Page 9 of 24
Step C - Connecting the tap
Models 30009UK and 37697UK
Measure and trim the red marked tube and / or the blue marked tube
and connect it to the hot water outlet and ambient outlet (if an ambient
model), on the top of the undersink unit. Use spring clamps provided.
Measure and trim the unmarked tube and connect it to the vent outlet on the
top of the undersink unit. Use spring clamps provided.
NOTE:
All tubes must have a continuous fall back to the undersink unit.
Connect the tap USB connector to the USB port on the undersink unit. Orient
the USB plug carefully and connect, do not force the plug. Once connected, fix
the cable to the wall, ensure it is away from any possible water splashes and
is off the floor.
NOTE:
When trimming any silicon tubes trim to minimum length, do not loop
any excess or allow kinking of the tubes. When connecting, slide the tube over
the pipe at least 25mm. There are black plastic clamps provided on the boiling
and chilled hoses to choke the flow if required. Only choke the flow if it is
excessively strong.
Model 437677UK - Domestic Compact Boiling /Chilled.
Measure and trim the blue tube and connect it to the chilled water outlet
located on the top rear, left hand side of the undersink unit. Use spring clamps
provided.
Measure and trim the red marked tube and connect it to the hot water outlet
located on the top rear, right hand side of the undersink unit. Use spring
clamps provided.
Measure and trim the unmarked tube and connect it to the vent outlet located
on the top rear centre of the undersink unit. Use spring clamps provided.
NOTE:
All tubes must have a continuous fall back to the undersink unit.
Connect the tap USB plug to the USB cable mounted socket from the
undersink unit. Orient the USB plug carefully and connect, do not force the
plug. Once connected, fix the cable to the wall, ensure it is away from any
possible water splashes and is off the floor.
Step D - Connecting the water supply
To prevent sediment from entering the Zip HydroTap at connection, flush water
through the supply line thoroughly before connection to the Zip HydroTap.
Open the access door and check that the filter is in place and secure. Connect
the water supply to the undersink unit using the attached flexible hose. Turn
on water and check for leaks. If no leaks are evident turn the power on.
Installation procedure
continued
Hot outlet
Vent
Chilled outlet
Compact model
USB and
Power cables
Hot outlet
Vent
Boiling ambient model
Ambient
outlet