background image

Page 17 of 24 

                                   

HydroTap Installation and Operating Instructions_Commercial_BCH 4in1_BH 3in1_October 2012_V1.05

Setting the Energy Saver Timer

Normal Operation Set Time 

To change time, press either Mode 

<

 or Mode  < button until Set Time is on the display screen. 

Press 

<

Adjust button to increase time or  < Adjust button to decrease time. Time increases 

or decreases in increments of one minute. Hold the Adjust buttons down for rapid increases or 
decreases. The time will be displayed in 24Hr mode.

Set Day 

Press either Mode 

<

 or Mode  < button until Set Day is displayed. 

Press

<

 Adjust or  < Adjust to select day.

Filter Life 

( factory set at 6000ltrs )

Press either Mode 

<

 or Mode  < button until Filter Life is displayed. 

Press 

<

 Adjust button to increase Filter Life or  < Adjust button to decrease Filter Life. 

Filter Life increases in 1000 Ltr increments to a maximum of 10000ltrs.

Reset Litres Filtered 

This function is to reset the Filter Change display after a filter has reached the end of its life (refer 
to “Replace Filter Instructions” section of this document).

Mode Plus Button

Mode Minus Button

Adjust Plus Button

Adjust Minus Button

Note:

Mode buttons  
change the 
screen options

Adjust buttons 
select the 
screen options

8.  Avoid touching the filter “O” rings and filter opening as this may cause 

bacterial contamination of the cartridge.

9.  Align cartridge tabs with the slots on the under-side of the filter head.

10.  Slide cartridge upward into head and rotate left to right until it stops.

11.  Locate the filter flush hose situated behind the filter cartridge and run to a 

container ready for flushing. Open the flush hose tap lever. On the control 
panel press adjust 

>

, this will start the water flushing the cartridge. 

Allow at least 7.5 Ltrs of water to run through to activate the filter and 
then press adjust 

>

 to stop the flow.

12.  Isolate the filter flush stop cock and re-fit behind the filter cartridge.

13.  Wipe up any spills and dispose of spent filter cartridge and packaging 

thoughtfully.

14.  Scroll through the menu to “Litres Filtered”, press adjust 

>

 to reset litre 

counter. Press adjust 

>

 and it asks “are you sure”. Press adjust 

>

 again 

to lock in the command. 

15.  Scroll through the menu to “Filter Used (Days)”, press adjust 

>

 to reset 

the timer. Press adjust 

>

 and it asks “are you sure”. Press adjust 

>

 

again to lock in the command. After approx 10 seconds it will default to 
the selected mode.

16.  Close the door to secure the appliance. 

 Warning:

 

If the Zip HydroTap is 

switched off for a long period of 
time (e.g. More than a weekend), 
run water through the chilled water 
outlet for at least 5 minutes before 
consumption.

Internal Filter Replacement 

(Continued)

Summary of Contents for HydroTap 4-in-1

Page 1: ...ydroTap 4 in 1 and Zip HydroTap 3 in 1 Filtered Boiling and Chilled water plus Hot and Cold water for kitchens and tea rooms Installation and Operating Instructions This Installation Instruction cover...

Page 2: ...HydroTap Installation and Operating Instructions_Commercial_BCH 4in1_BH 3in1_October 2012_V1 05...

Page 3: ...the under counter cupboard supporting the appliance is adequate for the total weight of the appliance when full of water Before Commissioning 1 Check the unit has been installed correctly 2 Check all...

Page 4: ...d BC assemblies which have been factory modified to accept a secondary mixer tap The mixer tap is connected so that it draws water directly from the cold water mains as well as from the boiling water...

Page 5: ...responsibility to supply if necessary and install all valves as required by local regulations and relevant standards The plumbing installation must be done in accordance with local Water Authority re...

Page 6: ...unit is intended for indoor use only and should never be installed outdoors or exposed to the elements of nature This unit must not be positioned in an area that may be cleaned by a water jet and mus...

Page 7: ...ation site Sufficient space in the cupboard to install the undersink unit in accordance with these Installation Instructions A table of dimensions is given above NOTE Add 65mm to the Depth of the unde...

Page 8: ...nut to the All Thread using the tube spanner supplied in the kit Check the Tap Head position before securing it tightly against the bench sink top NOTE 1 The tap assembly must not be positioned more...

Page 9: ...he undersink unit SPECIAL NOTE The HydroTap undersink units are heavy take note of the weights listed in the table on page 7 If you think you cannot lift the unit safely get help and avoid possible in...

Page 10: ...ny excess or allow kinking of the tubes When connecting slide the tube over the pipe at least 25mm There are black plastic clamps provided on the boiling and chilled hoses to choke the flow if require...

Page 11: ...responds to the direction indicated by the arrow on the filter head and by the instructions listed on the rear panel of the under sink unit Check the lower left hand John Guest fitting is the Inlet fr...

Page 12: ...and exit model description selection setting 4 The model selection is now complete The Start Filt Flush will be displayed Fig d Start Filt Flush Press Adjust Fig d Scroll Exit BC160 125 Press ADJUST o...

Page 13: ...nce to return to the service default screen To change the service default screen back to Normal Operation press the adjust buttons together until the screen changes back Warning Caution must be observ...

Page 14: ...n trap spigot available If a spigot is not available use the snap on spigot and worm drive clamps supplied in the kit Instructions and diagrams are supplied in the kit 8 Ensure the positioning of the...

Page 15: ...to be manually returned to the Off position Chilled Water Lever Depressing the Blue lever allows dispensing of Chilled water Pulling up the Blue lever allows the tap to operate in a no touch mode Wate...

Page 16: ...ox 10 seconds it will default to the selected mode The Zip HydroTap notifies when filter replacement is due The default setting is 6000 litres but this can be set in increments of 1000 litres from 100...

Page 17: ...touching the filter O rings and filter opening as this may cause bacterial contamination of the cartridge 9 Align cartridge tabs with the slots on the under side of the filter head 10 Slide cartridge...

Page 18: ...once and Monday Off will be displayed Now press Adjust until required time is reached If each individual day is to have an On Off time these steps need to be repeated for each day and for each On Off...

Page 19: ...enu and selecting de activate when Hot isolation Mode is displayed on the screen 7 The LCD will show Normal Operation Set The Boiling Chilled Water Dispensing Times The ability to change the maximum d...

Page 20: ...Boiling water to any one sink or may be fitted with a Font kit when a sink is not available The Font must be connected to a suitable drain NOTE The Venturi connection for the 4 in 1 Mixer tap is locat...

Page 21: ...lves 1 2 Page 22 Faulty restrictaflow valve Clean and reset restrictaflow valve item 3 Page 22 Water supply not connected Check plumbing connection turn water ON No hot water from mixer Hot tank empty...

Page 22: ...ion and Operating Instructions_Commercial_BCH 4in1_BH 3in1_October 2012_V1 05 Page 22 of 24 Trouble Shooting Continued 1 2 3 Item Description Part No 1 Chec Valve 15mm SP88508 2 Check Valve 8mm SP8850...

Page 23: ...Page 23 of 24 HydroTap Installation and Operating Instructions_Commercial_BCH 4in1_BH 3in1_October 2012_V1 05 Notes...

Page 24: ...s incurred by a Zip Service Provider or the cost of removal cartage and re installation of any component of the appliance if it needs to be returned for repair to Zip or its Distributor This warranty...

Reviews: