background image

Page 24 of 24                                 HydroTap Installation and Operating Instructions - 89650UK - August 2011 v1.02

The standard cup referred to in this publication is 167 ml (6 fl oz). 
The standard glass is 200 ml (7 fl oz). 
The terms “Zip” and “HydroTap” are registered trade marks of Zip Heaters (Aust) Pty Ltd. 
Zip products described in this publication are manufactured under one or more of the following 
patents: AU675601, AU637412, AU635979, GB0422305, GB2065848, US4354049, US5103859, 
and US5099825.  Other patents are in force and patent applications are pending. 

Head Office

Zip Heaters (UK) Ltd
14 Bertie Ward Way
Dereham
Norfolk NR19 1TE

Website:  www.zipheaters.co.uk
 sales@zipheaters.co.uk
Telephone: 0845 602 4533
Facsimile:  01362 692 448.

Warranty

Certain warranties may be implied by law into your contract with Zip. The warranty provided below is additional to these 
implied warranties and nothing set out below shall limit your statutory rights or rights at law. 
Zip Heaters (UK) Ltd warrants that, should any part fail within 12 calendar months of installation, that part will be 
repaired or replaced free of charge by Zip or its Distributor or Service Provider, except as set out below, provided 
the appliance is installed and used strictly in accordance with the instructions supplied, and that failure is not due 
to accident, misuse, abuse, unsuitable water conditions, or to any alteration, modification or repair by any party not  
expressly nominated by Zip. 
No costs are payable by the customer other than any mileage or travelling-time charges incurred by a Zip Service 
Provider or the cost of removal, cartage and re-installation of any component of the appliance if it needs to be returned 
for repair to Zip or its Distributor. 
This warranty does not cover damage resulting from non-operation of the appliance, the use of non authorised parts or 
consequential damage to any other goods, furnishings or property.
No warranty applies to the life of any filtration cartridge installed with the appliance as cartridge life may vary according 
to water quality and the rate of water consumption.  
Zip does not exclude, restrict or modify any liability that cannot be excluded, restricted or modified or which cannot, 
except to a limited extent, be excluded, restricted or modified as between the owner or user and Zip under the laws 
applicable. 
Furthermore, this warranty does not displace any statutory warranty, but, to the extent to which Zip is entitled to do 
so, the liability of Zip under any statutory warranty will be limited at Zip’s option to the replacement of the appliance or 
supply of equivalent appliance, the payment of the cost of replacing the appliance or acquiring an equivalent appliance, 
or the payment of the cost of having the appliance repaired or the repair of the appliance.

Registering Your Purchase

Registering your Zip installation on the Zip website may help to establish date of installation should it become necessary 
to service the appliance under terms of the Zip warranty. To register your installation go to www.zipheaters.co.uk and 
look under the heading “Warranty”.

As Zip policy is one of continuous product improvement, changes to specifications may be made without prior notice. 
Images in this booklet have been modified and may not be true representations of the finished goods.

Summary of Contents for HydroTap All-In-One BC 60/85A

Page 1: ...02 Page 1 of 24 Zip HydroTap All In One Filtered Boiling and Chilled water plus Hot and Cold water for kitchens and tea rooms Installation and Operating Instructions This Installation Instruction cov...

Page 2: ...ard supporting the appliance is adequate for the total weight of the appliance when full of water Before Commissioning 1 Check the unit has been secured correctly 2 Flush the supply line before connec...

Page 3: ...Replacement 16 Internal Filter Replacement 16 17 Operating the HydroTap 18 Child Safety Lock 18 Setting the Energy Saver Timer 19 20 Auxiliary Fan Attachment 21 Boiling Water Isolation 21 Setting Boil...

Page 4: ...nician To avoid hazards all installation procedures must be carried out by a suitably qualified tradesperson The power cable and power outlet must be in a safe visible position for connection Venting...

Page 5: ...r the same protection to the connecting pipework and fittings Altitude The HydroTap is equipped with a self calibrating program which caters for altitude adjustment Installation Environment Considerat...

Page 6: ...fy the model you are using Commercial Models A Boiling Chilled and Hot Cold Mains AV Boiling Chilled and Hot Cold Vented Boiling Water Capacity 160 160 cups in one hour 200 200 cups in one hour Capaci...

Page 7: ...cold water inlet at the rear of the unit Position the HydroTap undersink unit as close as possible to directly beneath the All in One tap head The connection tubes supplied with the tap head assembly...

Page 8: ...bolt plate system provided The following instruction is CRITICAL Adjust both cupboard door hinges and attach the supplied rubber door buffers to the doors to create a 4 mm air gap between the doors a...

Page 9: ...ugs from the John Guest fittings as shown in Figures 2 3 and 4 After suitably mounting the filter assembly to an adjacent surface measure and trim the filter inlet and filter outlet tubes Fit the tube...

Page 10: ...ox 5 minutes the unit will default to normal operation When starting both Boiling and Chilled cycles activate simultaneously after calibration has taken place the descriptions below indicate what happ...

Page 11: ...st to discuss the service issue Press the Menu minus button once to return to the service default screen To change the service default screen back to Normal Operation press the adjust buttons together...

Page 12: ...280 VENT OUTLET POSITION SILIC FRO IN H TO T NOTE IF THE FLOW RATE IS TOO FAST CUT THE RED SILICONE TUBE 75mm MINIMUM FROM THE BOTTOM OF THE BASE OF THE ALL IN ONE TAP INSERT THE TEFLON RESTRICTOR ABO...

Page 13: ...E NOT SUPPLIED 65 200 BENCHTOP CABINET DOOR 4mm BUFFER PAD TO ENSURE VENTILATION GAP SILICONE HOSE FROM BOILING WATER TANK IN HYDROTAP UNIT TO TAP SILICONE HOSE FROM CHILLED WATER TANK IN HYDROTAP UNI...

Page 14: ...IN HYDRTAP UNIT TO TAP Red SILICONE HOSE FROM CHILLED WATER TANK IN HYDROTAP UNIT TO TAP Blue SILICONE HOSE FROM STEAM VENT IN H TAP UNIT Clear BH2 B MAIN SUPP NOTE IF THE FLOW RATE IS TOO FAST CUT T...

Page 15: ...rating Instructions 89650UK August 2011 v1 02 Page 15 of 24 200 MAINS AMBIENT WATER SUPPLY ISOLATION VALVE NOT SUPPLIED ALL IN ONE TAP VENTED VERSION BH3 RED MARKER BLUE MARKER BH1 WHITE MARKER REAR V...

Page 16: ...ydroTap notifies when filter replacement is due The default setting is 6000 Ltrs but this can be set in increments of 1000Ltr from 1000Ltr to 10000Ltrs When a filter change is due the Change Filter li...

Page 17: ...onds it will default to the selected mode 16 Close the door to secure the appliance Internal Filter Replacement Warning If the Zip HydroTap is switched off for a long period of time e g more than a we...

Page 18: ...the Off position and repeat the step The lever has to be manually returned to the Off position Safety Lock The safety lock is designed to prevent the flow of boiling water if the hot lever is inadver...

Page 19: ...the sleep mode momentarily operate the Hot lever and then allow sufficient time for the water to reach the set temperature Filter Life Factory set at 6000 Litres Press either Menu or Menu button unti...

Page 20: ...revert to Normal operation mode To exit from the Service mode Press both the Adjust and Adjust buttons simultaneously and the screen will display Normal Operation If the buttons are not pressed toget...

Page 21: ...operation by Infirm or disabled persons 1 On the LCD scroll through the menu to Hot Isolation 2 Press adjust to activate 3 Now go to the Tap Head assembly and press the Safety Lock 3 three times rapi...

Page 22: ...ace faulty non return valves Faulty restrictaflow valve Clean and reset restrictaflow valve Water supply not connected Check plumbing connection turn water ON No hot water from mixer Hot tank empty Ex...

Page 23: ...ent Outside of the EU it will be necessary to dispose of this product at your local community waste collection or recycling centre In order to help preserve our environment we ask that you dispose of...

Page 24: ...Provider or the cost of removal cartage and re installation of any component of the appliance if it needs to be returned for repair to Zip or its Distributor This warranty does not cover damage resul...