Page 6 of 24 HydroTap Installation and Operating Instructions - 89650UK - August 2011 v1.02
Commercial Models Covered by These Instructions
Installation Requirements
(continued)
• For AV models, cold water supply with a minimum working pressure of 2 bar
(200 kPa) and a maximum working pressure of 7 bar (700 kPa) connected via
an isolation valve. For all A models, cold and hot water supply with a minumum
working pressure of 0.7 bar (70kpa) and a maximum working pressure of 7
bar (700 kPa). If pressure is likely to exceed 7 bar, install a 5 bar (500 kPa)
Pressure Limiting Valve.
• The fitting of an air flow vent, cut into the top half of the cupboard door
concealing the HydroTap requires a cut size of approximately 100mm circular,
to provide adequate warm air displacement. In installations where high volume
draw-off will occur, the fitting of the accessory exhaust fan is essential.
• Accessory exhaust fan must be fitted when supplied with 150/175 and
200/175+ models. Buffers must be fitted to cupboard door.
Important:
Do not proceed with the installation if these requirements are not met.
These Installation Instructions cover the A and AV HydroTap range. Use the chart
on the left to identify the model you are using:
Commercial Models:
A
= Boiling / Chilled and Hot / Cold. (Mains)
AV = Boiling / Chilled and Hot / Cold. (Vented)
Boiling Water Capacity:
160 = 160 cups in one hour** 200 = 200 cups in one hour**
** Capacity will be reduced by the volume of water used when operating the mixer tap.
Chilled Water Capacity:
125 = 125 glasses in one hour 175 = 175 glasses in one hour
Note:
The
Cup
measurement = 167mls, the
Glass
measurement = 200mls.
AV
Model
160
Cups of
Boiling Water
per Hour
125
Glasses of
Chilled Water
per Hour
Model
Height
mm (inch)
Depth
mm (inch)
Width
mm (inch)
Weight empty
kg’s lbs
Weight full
kg’s lbs
BC 60/85A
340 (13.3)
430 (16.9)
430 (16.9)
28
34.5
BC100/125A, BC160/125+A
BC100/125AV, BC160/125+AV
340 (13.3)
430 (16.9)
430 (16.9)
28 (61.7)
35 (77.1)
BC150/175A, BC200/175+A
BC150/175AV, BC200/175+AV
395 (15.5)
470(18.5)
500 (19.6)
29.5 (65)
38 (83.7)
Special Tools Required
In addition to normal tools, the following will be required:
• 50mm diameter sheet metal hole punch for sink tops. (not supplied)
• 50mm diameter hole saw for timber bench tops. (not supplied)
• Nut runner tube spanner (supplied) for fixing tap assembly.
Installation Procedure
Step A - Installing the All-in-One tap
(see P12-15)
1. Make sure that the tap location will allow the nozzle to drain into the sink.
NOTE 1: The tap assembly must not be positioned more than 900mm
above the HydroTap unit.
Failure to do this may result in poor water delivery.