Page 4 of 40
801910 - Zip Sparkling HydroTap - Installation Instructions - July 2014 - v1.00
Important Safety Instructions
What is the Zip HydroTap ?
The Zip HydroTaps are electronically controlled, filtered, Boiling, Chilled and Sparkling water, drinking
systems for kitchens and tea rooms. The HydroTap units are under bench drinking water appliances with a
dispensing tap mounted on a sink or bench, which may be used for residential or commercial applications.
These units utilise a conventional refrigerant compressor to chill the water and (for BCS) an immersion
heating element to boil the water and all utilise a CO2 gas cylinder to carbonate the chilled water. Depending
on the model, these units will dispense boiling water (factory set to 98°C) chilled water (factory set to 5-10°C)
These units are NOT designed to be used for sanitary fixtures.
The boiling water units are fitted with a tap mounted, child safety lock. In addition, there are various energy
saving options accessible via the main menu. Each boiling unit is equipped with a self-calibrating program
which caters for altitude adjustment. The 2.64kg CO2 bottle is refillable and should be returned to your
nearest HydroTap agency for exchange, whereas the water filter is a disposable item. Both will require
periodic replacement and are covered by a limited OEM warranty.
It is important that the Installation be done safely, correctly and completely, in order to utilise all the benefits
the HydroTap can provide. Each unit can be ordered with the Tap Head Assembly for Disabled use. The
disabled levers are supplied with Braille caps for the visually impaired.
This manual contains important safety, Installation instructions for the Zip HydroTap G4.
Safety
This appliance is not intended for use by persons (including children) with reduced physical,
sensory or mental capabilities, or lack of experience and knowledge, unless they have been
given supervision or instruction concerning use of the appliance by a person responsible for
their safety. Children should be supervised to ensure that they do not play with the appliance.
For products sold in Europe, this appliance can be used by children aged from 8 years and
above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge
if they have been given supervision or instruction concerning use of the appliance in a safe way and
understand the hazards involved. Children shall not play with the appliance. Cleaning and user maintenance
shall not be made by children without supervision.
Refrigerant
The Zip HydroTap unit contains R134A refrigerant under pressure. Maintenance of the refrigeration unit must
be carried out by an accredited service provider or qualified refrigeration technician.
Qualifications
If the power cable is damaged it must be repaired only by a qualified technician. To avoid hazards, all
Installation procedures must be carried out by a suitably qualified tradesperson. The power cable and power
outlet must be in a safe visible position for connection.
Venting
Sometimes steam and / or boiling water may discharge through a vent outlet at the tap. If the tap is not
installed using the Font pedestal, ensure the tap body is located so the tap outlet safely dispenses into the
sink bowl area.
Lifting
Take care when lifting the Zip HydroTap unit. Some units may exceed safe lifting limits. If you feel this is
beyond your personal capabilities, please seek assistance with the lift. The weights of the units are marked
on the packaging. Do not lift the unit by the front cover or any connections at the top rear of the unit. Refer to
section 1.2 technical specification for the weight of your product.
Airflow
The ambient temperatures this unit should operate within are 5ºC - 35ºC. Proper air circulation must be
provided. The system will operate satisfactorily only if the recommended air gaps of 50mm on each side are
provided. If a ventilation kit is supplied, it must be fitted. See technical specifications for correct Installation to
prevent overheating.