804050US v1.27 06.21 CS175 Install Instruction
Page 13 of 28
CO
2
Regulator
Pressure regulating knob
ON - OFF knob
Relief
valve
NOTE:
Take care not
to lose the small sealing
olive in the end of the
braided hose. This olive
is necessary to ensure
a gas tight seal between
the braided hose and the
regulator.
After replacing a bottle or after making a gas connection, perform a Leak Test:
Stage1:
1. Turn the gas OFF.
2. Using soapy water applied with a sponge, or with a brush, cover all of the
gas joints with a liberal amount of suds.
Stage 2:
1. Turn ON the gas.
2. Adjust the pressure to between 2.7-3.0 bar (39 - 43 psi).
3. Inspect the joint for leaks.
4. If any bubbles appear, the joint will need to be resealed.
Green zone
This gauge shows the pressure in the bottle and
indicates when the bottle is empty. Initial bottle
pressure will be 35-40 bar (507-580 psi) .
This gauge shows the adjustable limit (3.0±0.1 bar,
or 39±1 psi) required for the HydroTap to function
correctly