Page 14 of 28
804050US v1.27 06.21 CS175 Install Instruction
4.1
Hose and tube fitting
•
Remove all caps from the top of the
Command Center (except the mixer caps)
•
Only remove the mixer caps if a mixer
faucet is to be fitted.
•
Fit the foam insulation to the Blue and to
the White tubes after trimming them to
length
•
Install the mains water braided hoses to
the Command Center before locating the
unit in place.
NOTE: Do not overtighten
4.2
John Guest
fittings
(Insertion and removal)
Section 4
Command Center Installation
Con Strainer
90° Bend end
of Braided Hose
To HydroTap
Command Centre
Braided hose for
Mains Water Supply
From Mains
Water Supply
Be careful when cutting the poly tube so that there are no rough
edges and that the tube is not distorted.
1. Use a sharp knife to ensure the tube has a clean,
straight edge. Do not cut at an angle.
2. Remove any swarf or unwanted material.
3. Push the tube into the John Guest fitting making sure
all connections to the John Guest fittings are pushed in
past the “O”ring to full depth, at least 15mm (⅝”).
4. Check for a good joint by pulling back on the tube. If the
tube comes out, of the fitting, repeat the above step.
5. To remove the tube, press the collet into the fitting and
at the same time pull back on the tube.
1. Connect the white tube for sparkling water from the faucet
to the outlet of the carbonation valve.
2. Connect the white tube from the inlet of the carbonation
valve to the Sparkling Outlet connection on top of the
Command Center, as shown in Section 4.3.
3. See section 5.4 for carbonation valve flow rate adjustment.
4.3
Installing carbonation valve
To faucet
From Sparkling Outlet
of Command Centre