804050US v1.27 06.21 CS175 Install Instruction
Important Safety Instructions
WARNINGS
1. The Zip HydroTap Command Center must be earthed. The resistance of the earth
connection from each exposed metal part must be less than 1 ohm.
2. All Installation and service work must be completed by trained and suitably qualified
Tradespeople. Faulty operation due to unqualified persons working on this product, or
any other Zip product may void warranty coverage.
3. All Plumbing and Electrical must comply with local, state and federal codes.
4. All Plumbing and Electrical connections must be made in accordance with local regulations.
5. This HydroTap product is rated for 220-240V, 50-60Hz AC operation.
6. Command Centers must never be located near, or cleaned with water jets.
7. Zip HydroTaps are not to be exposed to the elements of nature
8. Due to the process of continuous improvement, Zip reserves the right to change details mentioned in
this manual, without notice.
9. If this device is not maintained and operated as specified in this document, there is a risk of exposure
to contaminants.
10. When dispensing hot water, the device can create a scald hazard.
11. If this device is not maintained and operated as specified in this document, there is a risk of exposure
to contaminants.
!
CO
2
Cylinder Warnings:
•
Pressurised container.
•
Protect from sunlight.
•
Contains gas under pressure, may explode if heated.
•
Do not expose to temperatures exceeding 50°C (122°F).
•
Do not pierce or burn, even after use.
•
Do not expose to naked flame or any incandescent material.
•
Keep out of reach of children.
•
High concentration of gas may cause asphyxiation.
•
Use only in ventilated areas.
•
Store in a location with a volume of no less than 50 cubic meters for each 6 lb bottle.
•
Use only in an upright position.
•
This bottle must be used with the approved pressure regulator.
•
Avoid shock.
•
Use according to MSDS (Material Safety Data Sheet).
Airflow
The ambient operating temperatures, when installed in a cabinet, must be between 5 - 35°C (41 - 95ºF). The
system will operate satisfactorily only with proper air ventilation. The recommended air gaps of 50mm (2”) on
each side, and 200mm (8”) above must be provided. See section 2 for correct ventilation details.
Positioning
It is important to ensure the Command Center is positioned in an accessible area close to the floor level. The
Command Center must have its base mounted in a horizontal position with all inlets and outlets facing up.
The Faucet must be located above the Command Center. See section 4 for details.