804050US v1.27 06.21 CS175 Install Instruction
Page 9 of 28
Before Installation
Before installing ensure that the following have been provided at the installation site:
•
Review all the technical specifications.
•
Ensure the underbench can support the product weight when full of water,
(allow an extra 5 kg (11 lb) when full. )
•
Sufficient space in the cabinet to install all of the Command Centers in accordance with these
Installation Instructions. Refer to technical specifications and section 4, for Installation instructions.
•
A 220-240V, 10A AC electrical power outlet will be required.
•
A potable water supply connection with isolating valve inside the cabinet within reach of the braided
hoses and positioned so that the connection point and the stop cock will not be obstructed when the
Command Centers are installed.
•
A cold water supply with a working pressure range of 250 - 700 kPa (37 - 100 psi) connected via an
isolation valve. Water inlet connection size is 1/2” BSP. The system shall only be supplied with cold
water.
•
Potable water should have a minimum TDS (Total Dissolved Solids) of 50 ppm. In areas where the
TDS exceeds 150 ppm and where mineral scale could be a problem, consideration should be given to
the maintenance required. Adding a water softener or reverse osmosis system should be considered.
•
Ensure sufficient space for ventilation, including minimum clearances and installation of vents. See
Section 2.
•
The appliance must be placed with its base in a horizontal position.
Note: Check all cable and hose lengths against inlet/outlet positions before proceeding (see Section
4 for general layout).
IMPORTANT! Do not proceed with installation if these requirements are not met.
!
Special Tools Required:
In addition to normal tools, the following will be required:
•
35mm (1⅜”) diameter sheet metal hole punch for sink tops (not supplied)
•
35mm (1⅜”) diameter hole saw for timber bench tops (not supplied)
•
Nut runner tube spanner (supplied) for fixing Classic faucet assemblies.
•
1
11
/
16
” AF Tube spanner or wrench (not supplied) for fixing the Arc/Cube Faucet assemblies
Section 1
Faucet Installation
Refer to the Faucet installation instruction book.