801910 v3.05 09.20 HT BCS Commercial Instructions
Page 27 of 32
7.3
Boiling Calibration (Boiling models)
Commissioning
7.4
Booster (240/175 models)
•
Press the calibration button and the system will
commence the Boiling calibration procedure. This
will take approx 8-10 minutes.
•
Upon completion, a Booster reminder screen will
appear and allow you to return home by pressing
the [Home] button.
NOTE:
Failing to make the correct selection for the “Booster” will affect product performance.
1. Press the [MENU] button for main menu.
2. Press the [Install] button.
3. Press the [Booster] button.
4. In the next screen, press YES to enable the Booster.
5. Turn the Booster ON
6. Water must be run through the Booster for a min of 30
seconds, before the heater will activate.
7. Dispense boiling water for 30 seconds and check the
Booster outlet hose is warm when the boiling water
tank is replenishing.
To enable Booster unit (when installed)