Page 32 of 40
802005UK - Residential (Boiling),chilled and sparkling installation instructions - Aug 2015 - v2.01
Installation instructions
Note
Mains hose length is 750mm.
Electrical power cable length is 1800mm.
Position the Command-Centre
TM
according to the
hose and cable lengths supplied.
Note
All plastic / silicon tubes must be trimmed to
size. They must have a constant fall to the
Command-Centre
TM
.
5.6 All-in-One 'Vented' tap
HydroTap
Mixer
Connections
RED
CLEAR
BRAIDED
POWER
CABLE
USB
MAINS
IN
MIXER
OUT
MIXER
IN
BOILING
OUT
BYPASS
OUT
VENT BYPASS
IN
BLUE
BRAIDED
CLEAR
CHILLED
OUT
SPARKLING
OUT
CO2
IN
Booster
Connections
T-Piece & Restrictaflow
(supplied)
External cold isolation valve
(not supplied)
Male to male adaptor
to T-Piece
(supplied)
535mm
280mm
50mm
50mm
Clearance
envelope
(Supplied)
Note
Neither the braided hoses or the tubes supplied with the tap, booster and ext. filter can be lengthened.
Take time to consider hose lengths when determining the mounting positions for the different options, also
ensure that the chilled and sparkling pipes are covered with the insulation provided.