806834 v1.02 07.21 G5 Online install instructions and user guide
26
Note 1
This appliance is intended for use with the Zip HydroTap G5 Command Centre.
Note 2
Water connections must be pointing vertically upwards.
Note 3
The booster unit should be installed as close as possible to the Zip HydroTap G5 as the
connection hoses cannot be lengthened.
3.6.4 Braided hose connections
• The cold water inlet (blue cap) and hot water outlet (red cap) are marked on the rating plate. Connect the
braided hoses from the ‘BYPASS OUT’ fitting on the Command Centre to the water inlet of the booster
(blue cap) and from the outlet of the booster (red cap) to the ‘BYPASS IN’ fitting on the Command Centre.
Avoid exerting mechanical force on the booster. This can be achieved by using a spanner on the flats of
the inlet and outlet connections when tightening the braided hose connectors.
• Do not over-tighten ! Tighten the braided hoses by hand, then turn a further 90° to 180° with a spanner.
• Once the water connections have been made, check for any leaks and rectify as necessary.
Booster
Hold connections
with spanner
while tightening hoses
3/8" BSP
connections
• Do not over tighten hose connections.
• Braided hoses supplied cannot be lengthened.
!
Strainer
Cold water into Booster,
connect to Command Centre
BYPASS OUT
Hot water out of Booster,
connect to Command Centre
BYPASS IN
!
Section 3.6 Booster system installation