- Device Reset Locally notification is Transmitted.
- Please use this procedure only when the network primary
controller is missing or otherwise inoperable.
LIGHT STATE & PRODUCT TEST
STATE
COLOR
LIGHT
ALARM SOUND
Power
Green
Normally on
No
Alarm
Red
Flashing
di”alarm
Malfunction
Yellow
Normally on
Long buzz
Test button of this sensor is used for testing wheater LED
indicator and buzzer can work properly. Red LED and yellow
LED flash alternatively with buzzer alarm when the test button
is pressed.
TROUBLESHOOTING
The sensor will keep alarming while the natural gas or LPG
density in air exceeds the alarm level:
1. Shut down the tube valve right away
2. Extinguish all fire sources
4. Avoid switching on various electric equipments
5. Open the windows to make air flow
SYMPTOM
REASON
SOLUTON
Alaways
warming up
after powering
on (LED keeps
flashing)
1. Long time
without power
2. Tested gas
detector while
warming up
1. Power on detector for
24 hours
2. Don’t test gas detector
while warming up
Yellow LED keeps
on and buzzer
keeps beeping
Gas sensor
faulty
Contact dealer for repair
The green LED lights up after power on the sensor, when a
“beep” sounds once, the sensor enters into warm-up state
then red and yellow LED flash alternately. Eventually the flash
stops 3 minutes later, which indicates that the sensor has
entered into normal working state. Don’t the senor while it’s
in warm-up state.
NETWORKING METHOD 2:
MANUAL NETWORK
In order to change network, long press the networking button
for 5 seconds, the green LED will flash slowly for 3 seconds,
which indicates that disconnection was successful.
DEVICE FACTORY RESET
- Long press Net_Button at least 10 seconds in the device.