- Device Reset Locally notification is Transmitted.

- Please use this procedure only when the network primary

  controller is missing or otherwise inoperable.

LIGHT STATE & PRODUCT TEST

STATE

COLOR

LIGHT

ALARM SOUND

Power

Green

Normally on

No

Alarm

Red

Flashing

di”alarm

Malfunction

Yellow

Normally on

Long buzz

Test button of this sensor is used for testing wheater LED 

indicator and buzzer can work properly. Red LED and yellow 

LED flash alternatively with buzzer alarm when the test button 

is pressed.

TROUBLESHOOTING

The sensor will keep alarming while the natural gas or LPG 

density in air exceeds the alarm level:

1. Shut down the tube valve right away

2. Extinguish all fire sources

4. Avoid switching on various electric equipments

5. Open the windows to make air flow

SYMPTOM

REASON

SOLUTON

Alaways 

warming up 

after powering 

on (LED keeps 

flashing)

1. Long time 

without power

2. Tested gas 

detector while 

warming up

1. Power on detector for 

24 hours

2. Don’t test gas detector 

while warming up

Yellow LED keeps 

on and buzzer 

keeps beeping

Gas sensor 

faulty

Contact dealer for repair

The green LED lights up after power on the sensor, when a 

“beep” sounds once, the sensor enters into warm-up state 

then red and yellow LED flash alternately. Eventually the flash 

stops 3 minutes later, which indicates that the sensor has 

entered into normal working state. Don’t the senor while it’s 

in warm-up state.

NETWORKING METHOD 2:

MANUAL NETWORK

In order to change network, long press the networking button 

for 5 seconds, the green LED will flash slowly for 3 seconds, 

which indicates that disconnection was successful.

 DEVICE FACTORY RESET

- Long press Net_Button at least 10 seconds in the device. 

Reviews: