OPERATION
ZIPPER MASCHINEN GmbH www.Zipper-Maschinen.at
25
ZI-STE6700DH & ZI-STE7500DSH
1.
To check the engine oil level, place the machine
on a safe, level surface. Switch off the engine and
allow the machine to stand for ten minutes so
that the circulating oil can collect in the oil pan.
2.
Unscrew the oil dipstick and wipe with a clean,
lint-free cloth or a non-fibrous paper towel.
3.
Push the dipstick into the opening, but do not
screw it in. (Make sure that the dipstick has really
been pushed in completely).
4.
Pull out the oil dipstick again and read off the oil
level. There are two markings for this - see
illustration on the left.
5.
If the oil level is low, refill the recommended oil
up to the upper edge
6.
Push in the oil dipstick again and tighten.
To operate the generator, use engine oil that meets the following requirements:
suitable for diesel engines
0W30 or 15W40
with classification CF/ CH-4/ or CI-4
For year-round operation, engine oil with SAE viscosity level 15W-40 is recommended.
13.1.2
Checking the fuel tank level
NOTICE
Observe the safety regulations for fuel control.
Filter the fuel during refuelling to
prevent foreign particles from entering the combustion chamber. Wipe up leaked fuel.
1.
Screw on the tank cap (sits on the fuel tank).
2.
Level check in the form of a visual inspection or via display. If necessary, top up
with diesel fuel with the appropriate standard EN 590.
3.
Close the fuel filler cap tightly after refuelling.
13.1.3
Check the air filter
Check the core of the air filter, ensuring that it is clean and performs well.
•
Loosen the screw on the cover of the filter, and then dismantle the cover to check the filter.
•
Please clean or change the filter if necessary.
NOTICE
•
Do not run the engine without the air filter, or else filth will enter the engine
through carburetor, resulting in quick wear and tear of the engine.
•
If the power output drops or the colour of the exhaust gases does not lock normal, renew the
air filter immediately.
13.1.4
Grounding
Before starting up the machine, have it grounded by a qualified electrician! If the machine
is intended for mobile operation, get a grounding cable with sufficient cross section from
your electrical retailer.