ASSEMBLY
ZIPPER MASCHINEN GmbH www.Zipper-Maschinen.at
29
ZI-ASA550ESA
1.
The electronic connection of the machine is designated for operation with a grounded
power socket (Mains voltage 230 V)!
2.
The connector plug may not be manipulated.
3.
The grounding wire should be held in green-yellow.
4.
The mains supply must be secured with 16A.
5.
Check that the mains voltage complies with the requirements of the machine.
6.
In case of repair or replacement, the grounding conductor must not be connected to a
live box!
7.
Make sure that a possible extension cord is in good condition and suitable for the
transmission of power. An undersized cord reduces the transmission of power and heats
up.
8.
A damaged cable must be replaced immediately
N O T I C E
Operation is only allowed with safety switch against stray current (RCD
max. stray current of 30mA).
N O T I C E
Use only permitted extension cable with cross-section the one in the
following table declared.
Voltage
Extension
Cross-section
220 V-240 V
50 Hz
<27 m
1,5 mm
2
<44 m
2,5 mm
2
<70 m
4,0 mm
2
<105 m
6,0 mm
2
12.5
Assembly
1.
Assembly of the wheels on the base frame
-
Insert the screw M10x75 together with a washer
Ø10 through the wheel on the front.
-
Slide the 2nd washer Ø10 + spring washer A10 on
the screw and secure using a nut M10.
Attention: Do not tighten the nut too tight.
Rotating the wheel with your hand must be
possible!
-
Screw the wheel in the axle of the base frame (F)
and tighten the nut against the axle. Attach the
wheel cap (R).