TROUBLE SHOOTING
ZIPPER MASCHINEN GmbH www.Zipper-Maschinen.at
21
ZI-EBM40V-AKKU
Check regularly the condition of the machine
14.1
Cleaning
After each use, the machine and all its parts must be thoroughly cleaned.
NOTICE
The usage of certain solutions containing ingredients damaging metal surfaces
as well as the use of scrubbing agents will damage the machine surface!
Never use running water or a high pressure cleaner to clean the machine.
Clean the machine after each use with a dry cloth or with a brush if it is very dirty.
- Keep the ventilation slots clean and dust-free.
- Remove the soil auger or mixer from the machine and clean it thoroughly before cleaning.
14.2
Storage
Clean all components thoroughly before storage.
Store the machine separately in a dry room at not less than -10°C.
Store the battery and charger separately from the machine.
Please observe and follow the storage conditions for the battery and charger as described in
their instructions.
14.3
Disposal
Do not dispose the machine in residual waste. Contact your local authorities for information
regarding the available disposal options. When you buy at your local dealer for a replacement
unit, the latter is obliged to exchange your old.
15
TROUBLE SHOOTING
WARNING
Danger due to electrical voltage! Manipulating the machine when connected to
the power source can cause serious injury or death. Always disconnect the machine
from the power supply before troubleshooting and secure it against unintentional
restarting! Repair work may only be carried out by qualified personnel!
When you are unable to carry out necessary repairs properly and/or do not have the required skills to
do so, always contact a specialist to help you in solving the problem.
Trouble
Possible cause
Solution
Motor does not start
Battery is not plugged in
plug in battery
Battery is not charged
Recharge battery
Safety switch is damaged
Check safety switch
Switch is damaged
Check switch
Battery cannot charged
anymore
Contact failure
Check contact pins
Battery damaged
Change battery