OPERATION
ZIPPER MASCHINEN GmbH www.Zipper-Maschinen.at
44
ZI-RWM84
18.6.2
Calibration nominal diameter D
Press the Fn, D+ and D- keys simultaneously
to enter the program.
The display shows C
AL
| 17.0.
Enter the value of the nominal diameter D
using the D+/D- keys.
Pull out the front gauge arm until it touches
the rim edge.
Press the ALU key to save the data and to
complete the calibration.
18.7
Presetting user data
Four different user data can be preset to the
memory to save operation time.
Press
the
USER key repeatedly to switch to
the desired user (e.g. User 2).
The corresponding user number lights up on
the display.
Enter the dimensions for A, W and D manually
or using the automatic gauges.
Press the Fn key and the USER key
simultaneously to save the entered data.
18.8
Balance a wheel
18.8.1
Standard dynamic balance
The dynamic balance mode is preset as standard mode.
In the dynamic measuring run, clip-on weights
must be attached to both sides of the rim flange
(see graphic left).
Procedure:
Step 1: Set wheel dimesions A, W and D.