19
2.8
Electrical Safety
When equipment like this is being started a short-time
voltage drop may occur, particularly if the mains
quality is poor. Such drops can affect other consumers
(e. g. flickering of a lamp). At a mains impedance of
Zmax < 0.448 Ω, such trouble is not
to be expected. (For further information, please con-
tact your local energy supply company.)
2.9
Electrical Connection
The three-phase 400 V/50 Hz motor of this log split-
ter should be connected to a standard 400 V + 10
%/50 Hz + 1 Hz power supply source provided with a
residual-current circuit breaker. The main connection
and any extension cables must have five wires = 3P +
N + PE (3/N/PE). Also, the main connection must be
fused (16 A max.) Electric cables must be of H 07 RN
type and in conformity with EN 60245.
2.10
Assembly and Preparation
Unpacking
(Fig. 1.2)
.
Unpacking this log splitter requires at least two persons. To place the log splitter on the floor, proceed
step by step as described below. Ensure that block (B) supports the log splitter box (A) at a point above
its middle. The other end of block (B) should rest
on a fixed object such as a wall. Fasten wedge (C) under the lifted box to prevent the latter from slipping
off. After that, you can remove the packing carton from the log splitter. Assembly
(Fig. 1.3)
1. Pull out spring (A) to release lock (B). Apply a thin film of grease to the points marked in the sketch
below. Then insert the lever and make sure that it has reached its intended end position (C). Now, latch
the lever by lock (B) and spring (A). Perform the same procedure for the other lever.
2. You can set three different table positions to be able to split logs of various lengths. Insert the ta-
ble into one of the three fixtures (E) provided for this purpose and turn hooks (D) by 90° lock it on
eitheside.
I M P O R T A N T
Make sure that the electric circuit is
fused, and that the power, voltage
and frequency of the motor is sup-
ported by your mains supply. Also,
make sure, that your power supply is
earthed. Connect your log splitter to
earth. Never open the ON/OFF
switchbox. However, if it should be-
come necessary to do so, contact a
skilled electrician. Make sure that you
will never touch live contacts, specifi-
cally when you plug or unplug your
log splitter. This machine and its
power cord must never get into con-
tact with water. Never use its power
cord to move/shift your log splitter.
Always unplug the power cord before
handling your log splitter. Do not
yank the plug out of the wall socket
by the cable and protect the latter
against heat sources, oil and objects
which can damage it. Neither expose
your log splitter to rain nor to wet-
ness.
C A U T I O N
Any unprofessional use of exten-
sion cables can cause overheat-
ing of this log splitter.
Ensure that
the extension cable is not longer
than 10 m and its wire cross section
is not less than 2.5 mm². Never use
uninsulated or bare cables, respec-
tively. The extension cable must be
suitable for outdoor use.
Summary of Contents for ZI-HS7
Page 3: ...3 Fig 1 Fig 1 1 ...
Page 4: ...4 Fig 1 2 Fig 1 3 ...
Page 5: ...5 Fig 8 ...
Page 13: ...13 1 16 Výkres a seznam náhradních dílů ...
Page 24: ...24 2 16 Spare part drawings and spare part lists ...
Page 27: ...27 ...