22
2.8
Electrical Safety
When equipment like this is being started a
short-time voltage drop may occur, particularly
if the mains quality is poor. Such drops can af-
fect other consumers (e. g. flickering of a lamp).
At a mains impedance of Zmax < 0.448
Ω
, such
trouble is not
to be expected. (For further information, please
contact your local energy supply company.)
2.9
Electrical Connection
The three-phase 400 V/50 Hz motor of this log
splitter should be connected to a standard 400 V
+ 10 %/50 Hz + 1 Hz power supply source pro-
vided with a residual-current circuit breaker. The
main connection and any extension cables must
have five wires = 3P + N + PE (3/N/PE). Also,
the main connection must be fused (16 A max.)
Electric cables must be of H 07 RN type and in
conformity with EN 60245.
2.10
Assembly and Preparation
Unpacking
(Fig. 1.2)
.
Unpacking this log splitter requires at least two persons. To place the log splitter on the floor, pro-
ceed step by step as described below. Ensure that block (B) supports the log splitter box (A) at a
point above its middle. The other end of block (B) should rest
on a fixed object such as a wall. Fasten wedge (C) under the lifted box to prevent the latter from
slipping off. After that, you can remove the packing carton from the log splitter. Assembly
(Fig.
1.3)
I M P O R T A N T
Make sure that the electric circuit is
fused, and that the power, voltage and
frequency of the motor is supported by
your mains supply. Also, make sure,
that your power supply is earthed.
Connect your log splitter to earth. Nev-
er open the ON/OFF switchbox. How-
ever, if it should become necessary to
do so, contact a skilled electrician.
Make sure that you will never touch
live contacts, specifically when you
plug or unplug your log splitter. This
machine and its power cord must never
get into contact with water. Never use
its power cord to move/shift your log
splitter. Always unplug the power cord
before handling your log splitter. Do
not yank the plug out of the wall sock-
et by the cable and protect the latter
against heat sources, oil and objects
which can damage it. Neither expose
your log splitter to rain nor to wetness.
C A U T I O N
Any unprofessional use of exten-
sion cables can cause overheating
of this log splitter.
Ensure that the
extension cable is not longer than 10
m and its wire cross section is not less
than 2.5 mm². Never use uninsulated
or bare cables, respectively. The ex-
tension cable must be suitable for
outdoor use.
Summary of Contents for ZI-HS7H
Page 4: ...4 Fig 1 Fig 1 1 ...
Page 5: ...5 Fig 1 2 Fig 1 3 ...
Page 6: ...6 Fig 8 ...
Page 16: ...16 1 15 Spare part drawings and spare part lists ...
Page 28: ...28 2 16 Spare part drawings and spare part lists ...
Page 39: ...39 2 32 Despiece ...
Page 50: ...50 3 16 Vue éclatée ...
Page 59: ...59 3 32 Výkres a seznam náhradních dílů ...
Page 67: ...67 ...