2 scanning modes:
• AC SCAN
locates live, unshielded AC wires up to 2"
(50 mm) deep
• METAL SCAN
locates ferrous (magnetic) metal,
such as steel, up to 3" deep (75 mm), and non-ferrous
(non-magnetic) metal, such as copper piping, up to 1
1
⁄
2
"
(38 mm) deep
The advanced ColorTrip Display lights red in AC SCAN
Mode and blue in METAL SCAN Mode.
WireWarning
Detection
automatically detects and alerts for live AC
(alternating current) wires in both modes. When AC voltage
is detected, the display will flash red.
INSTALL 9-VOLT BATTERY
Always use new alkaline batteries
with an extended expiration
date at least 3 years beyond the
current date. Be sure not to pull
on wires when disconnecting an
old battery.
Low Battery Indicator
will
flash when battery charge
is too low for scanner to
function properly.
WARNING
Do not rely exclusively on the
scanner to locate items behind
a surface. Use other information to help locate
items before penetrating the surface, including
construction plans, visible points of entry of pipes
and wiring into walls such as in a basement,
and in standard stud-spacing practices.
ElectriScanner
™
e60c
AC Scanner with Metal Detection
EN
NOTE: AC SCAN only detects live (hot) unshielded
AC wiring. Refer to the WARNING Statement under
WireWarning Detection below for important details
and warnings about AC detection.
WIREWARNING
DETECTION
The Zircon
®
WireWarning
Detection feature works continuously in both modes.
When live AC voltage is detected in METAL SCAN Mode,
the warning indicator shows and the display flashes red. If
scanning begins over a live AC wire, the indicator or middle
bars (in AC SCAN) will flash on the red display continuously.
Use extreme caution under these circumstances, or whenever
live AC wiring is present.
WARNING
THE SCANNER MAY NOT DETECT
LIVE CURRENT IF WIRES ARE MORE
THAN 2" (50 mm) BELOW THE SCANNED SURFACE,
IN CONCRETE, ENCASED IN CONDUIT, BEHIND A
PLYWOOD SHEAR WALL OR METALLIC WALL
COVERING, OR IF MOISTURE IS PRESENT IN THE
ENVIRONMENT OR SCANNED SURFACE.
SCAN FOR METAL
Use METAL SCAN to locate ferrous (magnetic) metal,
such as structure steel or rebar, up to 3" (75 mm) below
the scanned surface, or non-ferrous (non-magnetic) metal,
such as copper piping, up to 1
1
⁄
2
" (38 mm) scanned
surface.
1.
Set mode to METAL SCAN.
2.
For maximum sensitivity, press and hold Power Button.
Hold the scanner away from the surface until a short beep
confirms calibration is complete, then place against the
surface to be scanned.
3.
While continuing to hold Power Button, slide the
scanner slowly against the wall. For a strong read,
the SpotLite Pointer will shine, a steady beep will sound,
and the Target Indicator will display. (
Figure B
)
4. Mark the spot
where the most Target Indication
Bars display. (
Figure C
)
5.
Continue sliding in same direction until bars reduce,
then reverse direction.
Mark the spot
where the most
Target Indication Bars display. (
Figure D
) The midpoint
between the two marks is the location of the metal object.
NOTE: If the scanner indicates a large area of
metal, refine the scan to narrow the scanned area.
SELECT MODE / POWER UP
Move Mode Selector Switch to desired mode:
AC SCAN
or
METAL SCAN.
To activate scanner, press and hold Power Button.
If button is not pressed and held, unit shuts off.
SCAN FOR AC (alternating current)
Use AC SCAN to find live (hot),
unshielded wiring, up to 2" (50
mm) below the scanned surface.
ALWAYS TURN OFF POWER
WHEN WORKING NEAR
ELECTRICAL WIRES (EXCEPT
WHEN SCANNING).
For best results, hold the scanner
as shown (
Figure A
) and move
slowly when scanning.
Do not
touch the surface during
calibration or scan.
1.
Set mode to AC SCAN.
2.
Hold scanner flat against wall,
then press and hold Power Button.
A short beep confirms that
calibration is complete.
DO NOT MOVE SCANNER
DURING CALIBRATION.
3.
While holding Power Button,
slide the scanner slowly against the
wall. For a strong read, the SpotLite
Pointer will shine, a steady beep
will sound, and the Target Indicator
will display. (
Figure B
)
4. Mark the spot
where the
most Target Indication Bars show
on the display. (
Figure C
)
5.
Continue in same direction
until bars reduce, then reverse
direction.
Mark the spot
where
the display bars peak. (
Figure D
)
The midpoint between the two
marks is the location of the live
AC wiring. (
Figure E
)
If the unit indicates live electricity
over a large area, reduce the
sensitivity of the scanner to refine
the scanning area and more
accurately locate the live AC wiring
(see REFINE THE AC SCAN below).
WARNING
DO NOT ASSUME THERE ARE NO LIVE
ELECTRICAL WIRES IN THE WALL. DO
NOT TAKE ACTIONS THAT COULD BE DANGEROUS IF
THE WALL CONTAINS A LIVE ELECTRICAL WIRE.
ALWAYS TURN OFF THE ELECTRICAL, GAS, AND
WATER SUPPLIES BEFORE PENETRATING A SURFACE.
FAILURE TO FOLLOW THESE INSTRUCTIONS MAY
RESULT IN ELECTRIC SHOCK, FIRE, AND/OR SERIOUS
INJURY OR PROPERTY DAMAGE.
REFINE THE AC SCAN
1.
Release Power Button, then position the scanner
over one of the previous marks. This will reset to a lower
sensitivity and narrow the scan area.
2.
Press and hold Power Button, then repeat steps 3–5
under SCAN FOR AC.
3.
Repeat as needed for increased accuracy.
REFINE THE METAL SCAN
1.
Release Power Button, then position the scanner
over one of the previous marks. This will reset to a lower
sensitivity and narrow the scan area.
2.
Press and hold Power, then repeat steps 3-5 under
SCAN FOR METAL.
3.
Repeat as needed for increased accuracy.
NOTE: If any bars display, metal is present.
Small targets or targets deep below the surface
may only show two or four bars, and the scanner
may not be able to locate the center of the metal.
WORKING WITH DIFFERENT MATERIALS
Wallpaper
This scanner functions normally on walls
covered with wallpaper or fabric, unless the materials are
metallic foil, contain metallic fibers, or are still wet after
application. Wallpaper may need to dry for several weeks
after application.
Freshly painted walls
Paint may take a week or longer
to dry after application.
Lath and plaster
Use METAL SCAN to locate the nail
heads holding wood lath to the studs. If the plaster has
metal mesh reinforcement, the scanner will be unable to
detect studs through that material.
Highly textured walls, acoustic ceilings, wood
flooring, subflooring, or gypsum drywall over
plywood sheathing
Use METAL SCAN mode to locate
nails or screws that may line up vertically where a stud or
joist is positioned.
Electrical wiring and pipes
Caution should always
be used when nailing, cutting,
or drilling in walls, floors,
and ceilings that may contain these items.
NOTE: Sensing depth and accuracy can vary
depending on scanning environment conditions
such as mineral contents, moisture, texture and
consistency of the wall materials.
TROUBLESHOOTING & CONSTRUCTION TIPS
SITUATION
LIKELY CAUSE
SOLUTION
Area of voltage
appears larger than
actual wire during
AC SCAN.
Voltage detection can
spread on drywall by as
much as 12" (30 cm) on
each side of the wire.
Narrow the scan detection:
1.
Turn scanner off.
2.
Turn it on again at the
edge of where the wire was first detected.
3.
Repeat scan.
Difficulty detecting
metal.
Scanner was calibrated
over metal object or
metal object is too deep
or too small.
• The scanner may have been calibrated over a metal object, reducing
sensitivity. Try calibrating in another location.
• Scan in both horizontal and vertical directions. Metal sensitivity is increased
when metal object is parallel to sensor.
Metal object reading
appears wider than
actual size.
Scanner sensitivity is
calibrated too high.
To reduce sensitivity in METAL SCAN Mode, recalibrate scanner over either of
first two marks (see steps under SCAN FOR METAL).
Display flashes red
continually at start
of scan.
Scanner was calibrated
directly over an area of
live AC.
Release the Power Button, slide the tool a few inches (5−8 cm) to the left or
right, and repeat scan.
Electrical wires
suspected but none
detected.
Wires are shielded by a
metal conduit, braided
wire, or metallic wall
covering.
Use METAL SCAN Mode to scan for metal, wire, or metal conduit.
Wires deeper than
2" (50 mm) from the
surface might not be
detected.
If there is an outlet switch, turn it to ON position while scanning, but turn OFF
when working near the wires. Use extra caution if the area has plywood, thick
wood backing behind drywall, or walls that are thicker than normal.
Wires may not be live.
Plug a lamp into the outlet and turn it on to test whether wires are live.
Low Battery Indicator
flashes and scanner
does not operate.
Low battery.
Install new 9-volt alkaline battery with an extended expiration date.
SpotLite
®
Pointer
Mode
Selector
Switch
Battery
Door Tab
Target
Indicaton
Bars
Ergonomic
Rubber Grip
Power
Button
METAL SCAN
Mode Indicator
Low Battery
Indicator
Target Indicator
AC SCAN Mode /
WireWarning
®
Detection
Indicator
Figure A
Figure B
Figure C
Figure D
Figure E
BEFORE YOU BEGIN
- Always use new alkaline batteries with an extended expiration date at least 3 years beyond the current date.
- Do not rely exclusively on the scanner to locate items behind a surface. Use other information to help locate such items
before penetrating the surface, including construction plans, visible points of entry of pipes and wiring into walls such as
in a basement, and standard stud-spacing practices.
- Readings should always be consistent and repeatable.
- Zircon scanners are recommended for interior use only.
- Other objects commonly contained in walls, floors, or ceilings are water pipes, gas lines, firestops, and electrical wiring.
- Sensing depth and accuracy can vary depending on scanning environment conditions such as mineral content, moisture,
texture and consistency of the wall materials.
- Always turn off power when working near electrical wires (except when scanning).
- Due to the proximity of electrical wiring or pipes to the wall surface, caution should always be used when nailing,
cutting, or drilling in walls, floors, and ceilings that may contain these items.
Visit www.zircon.com for the
most current instructions.
FCC Part 15 Class B Registration Warning: This device complies
with Part 15 of FCC Rules. Operation is subject to the following
two conditions: (1) this device may not cause harmful interference,
and (2) this device must accept any interference received, including
interference that may cause undesired operation.
ZirconCorporation
ZirconTV
ZirconTools
|
ZirconToolPro
ZirconTools
LIMITED 1 YEAR WARRANTY
Zircon Corporation (“Zircon”) warrants to the product
owner that this product will be free from defects in
materials and workmanship for one year from the
original date of purchase. Any defective product
returned to Zircon within the warranty period to the
address below, freight prepaid, along with proof of
purchase, will be repaired or replaced, at Zircon’s
option. Repair or replacement may be made with a
new or refurbished product or components, at Zircon’s
sole discretion. If the returned product is no longer
available, Zircon may replace the product with a
similar product of similar function. This warranty is
limited to the electronic circuitry of the product and
original case of the product, and specifically excludes
any damage caused by abuse, modification, handling
contrary to these instructions, other unreasonable use,
or neglect. This is your sole and exclusive remedy for
breach of this Limited Warranty.
This Limited Warranty is in lieu of all other warranties,
express or implied, and no other representations or
claims of a similar nature will bind or obligate Zircon.
Any implied warranties applicable to this product
that cannot be disclaimed are limited to the one year
period following its purchase. This Limited Warranty
does not cover consumable parts, including batteries,
or software, even if packaged with the product.
IN NO EVENT WILL ZIRCON BE LIABLE FOR ANY
SPECIAL, INCIDENTAL OR CONSEQUENTIAL DAMAGES
RESULTING FROM POSSESSION, USE OR MALFUNCTION
OF THIS PRODUCT.
Some states do not allow limitations on certain
implied warranties and/or the limitation on incidental
or consequential damages, so the above limitations
and exclusions may not apply to you. This warranty
gives you specific legal rights, and you may also have
other rights which vary from state to state.
Return products for warranty service, freight prepaid
with proof of purchase (a dated sales receipt) to:
Zircon Corporation, Attn: Returns Department
1580 Dell Avenue
Campbell, CA 95008-6992 USA
Be sure to include your name and return address.
Allow 4–6 weeks for delivery.
Customer Service: 1-800-245-9265 or 1-408-963-4550
Monday–Friday, 8:00 a.m.–5:00 p.m. PT
info@zircon.com • www.zircon.com
©2018 Zircon Corporation • P/N 68969 • Rev D 05/18
ColorTrip, ElectriScanner, SpotLite, WireWarning,
and Zircon are registered trademarks or trademarks
of Zircon Corporation.
ColorTrip
™
Display