background image

2 scanning modes:

• AC SCAN

 locates live, unshielded AC wires up to 2" 

(50 mm) deep

• METAL SCAN

 locates ferrous (magnetic) metal,  

such as steel, up to 3" deep (75 mm), and non-ferrous 

(non-magnetic) metal, such as copper piping, up to 1

1

2

"  

(38 mm) deep

The advanced ColorTrip Display lights red in AC SCAN 

Mode and blue in METAL SCAN Mode. 

WireWarning

 

Detection

 automatically detects and alerts for live AC 

(alternating current) wires in both modes. When AC voltage 

is detected, the display will flash red.

INSTALL 9-VOLT BATTERY

Always use new alkaline batteries 

with an extended expiration 

date at least 3 years beyond the 

current date. Be sure not to pull 

on wires when disconnecting an 

old battery.

Low Battery Indicator

 will 

flash when battery charge  

is too low for scanner to  

function properly.

WARNING

Do not rely exclusively on the 

scanner to locate items behind  

a surface. Use other information to help locate 

 items before penetrating the surface, including 

construction plans, visible points of entry of pipes 

and wiring into walls such as in a basement, 

and in standard stud-spacing practices.

ElectriScanner

 e60c

AC Scanner with Metal Detection

EN

NOTE: AC SCAN only detects live (hot) unshielded 

AC wiring. Refer to the WARNING Statement under 

WireWarning Detection below for important details 

and warnings about AC detection.

WIREWARNING

 

DETECTION  

The Zircon

®

 WireWarning 

Detection feature works continuously in both modes. 

When live AC voltage is detected in METAL SCAN Mode, 

the warning indicator shows and the display flashes red. If 

scanning begins over a live AC wire, the indicator or middle 

bars (in AC SCAN) will flash on the red display continuously.

Use extreme caution under these circumstances, or whenever 

live AC wiring is present.

WARNING

THE SCANNER MAY NOT DETECT  

LIVE CURRENT IF WIRES ARE MORE 

THAN 2" (50 mm) BELOW THE SCANNED SURFACE, 

IN CONCRETE, ENCASED IN CONDUIT, BEHIND A 

PLYWOOD SHEAR WALL OR METALLIC WALL 

COVERING, OR IF MOISTURE IS PRESENT IN THE 

ENVIRONMENT OR SCANNED SURFACE. 

SCAN FOR METAL

Use METAL SCAN to locate ferrous (magnetic) metal,  

such as structure steel or rebar, up to 3" (75 mm) below 

the scanned surface, or non-ferrous (non-magnetic) metal, 

such as copper piping, up to 1

1

2

" (38 mm) scanned 

surface.

1. 

Set mode to METAL SCAN.

2. 

For maximum sensitivity, press and hold Power Button. 

Hold the scanner away from the surface until a short beep 

confirms calibration is complete, then place against the 

surface to be scanned.

3. 

While continuing to hold Power Button, slide the 

scanner slowly against the wall. For a strong read,  

the SpotLite Pointer will shine, a steady beep will sound, 

and the Target Indicator will display. (

Figure B

)

4.  Mark the spot

 where the most Target Indication 

Bars display. (

Figure C

)

5. 

Continue sliding in same direction until bars reduce, 

then reverse direction. 

Mark the spot

 where the most 

Target Indication Bars display. (

Figure D

) The midpoint 

between the two marks is the location of the metal object.

NOTE: If the scanner indicates a large area of 

metal, refine the scan to narrow the scanned area.

SELECT MODE / POWER UP

Move Mode Selector Switch to desired mode:  

AC SCAN 

or 

METAL SCAN.

To activate scanner, press and hold Power Button. 

If button is not pressed and held, unit shuts off. 

SCAN FOR AC (alternating current)

Use AC SCAN to find live (hot), 

unshielded wiring, up to 2" (50 

mm) below the scanned surface.

ALWAYS TURN OFF POWER 

WHEN WORKING NEAR 

ELECTRICAL WIRES (EXCEPT 

WHEN SCANNING).

For best results, hold the scanner 

as shown (

Figure A

) and move 

slowly when scanning. 

Do not 

touch the surface during 

calibration or scan.

1. 

Set mode to AC SCAN.

2. 

Hold scanner flat against wall,  

then press and hold Power Button. 

A short beep confirms that 

calibration is complete.  

DO NOT MOVE SCANNER  

DURING CALIBRATION.

3. 

While holding Power Button, 

slide the scanner slowly against the 

wall. For a strong read, the SpotLite 

Pointer will shine, a steady beep 

will sound, and the Target Indicator 

will display. (

Figure B

)

4.  Mark the spot

 where the 

most Target Indication Bars show 

on the display. (

Figure C

)

5. 

Continue in same direction 

until bars reduce, then reverse 

direction. 

Mark the spot

 where 

the display bars peak. (

Figure D

The midpoint between the two 

marks is the location of the live  

AC wiring. (

Figure E

)

If the unit indicates live electricity 

over a large area, reduce the 

sensitivity of the scanner to refine 

the scanning area and more 

accurately locate the live AC wiring 

(see REFINE THE AC SCAN below).

WARNING

DO NOT ASSUME THERE ARE NO LIVE 

ELECTRICAL WIRES IN THE WALL. DO 

NOT TAKE ACTIONS THAT COULD BE DANGEROUS IF 

THE WALL CONTAINS A LIVE ELECTRICAL WIRE. 

ALWAYS TURN OFF THE ELECTRICAL, GAS, AND 

WATER SUPPLIES BEFORE PENETRATING A SURFACE. 

FAILURE TO FOLLOW THESE INSTRUCTIONS MAY 

RESULT IN ELECTRIC SHOCK, FIRE, AND/OR SERIOUS 

INJURY OR PROPERTY DAMAGE. 

REFINE THE AC SCAN

1. 

Release Power Button, then position the scanner 

over one of the previous marks. This will reset to a lower 

sensitivity and narrow the scan area. 

2. 

Press and hold Power Button, then repeat steps 3–5 

under SCAN FOR AC.

3. 

Repeat as needed for increased accuracy. 

REFINE THE METAL SCAN

1. 

Release Power Button, then position the scanner 

over one of the previous marks. This will reset to a lower 

sensitivity and narrow the scan area. 

2. 

Press and hold Power, then repeat steps 3-5 under 

SCAN FOR METAL.

3. 

Repeat as needed for increased accuracy. 

NOTE: If any bars display, metal is present.  

Small targets or targets deep below the surface 

may only show two or four bars, and the scanner 

may not be able to locate the center of the metal.

WORKING WITH DIFFERENT MATERIALS

Wallpaper  

This scanner functions normally on walls 

covered with wallpaper or fabric, unless the materials are 

metallic foil, contain metallic fibers, or are still wet after 

application. Wallpaper may need to dry for several weeks 

after application.

Freshly painted walls  

Paint may take a week or longer 

to dry after application.

Lath and plaster

  Use METAL SCAN to locate the nail 

heads holding wood lath to the studs. If the plaster has 

metal mesh reinforcement, the scanner will be unable to 

detect studs through that material. 

Highly textured walls, acoustic ceilings, wood 

flooring, subflooring, or gypsum drywall over 

plywood sheathing

  Use METAL SCAN mode to locate 

nails or screws that may line up vertically where a stud or 

joist is positioned. 

Electrical wiring and pipes

  Caution should always  

be used when nailing, cutting, 

or drilling in walls, floors, 

and ceilings that may contain these items.

NOTE: Sensing depth and accuracy can vary 

depending on scanning environment conditions 

such as mineral contents, moisture, texture and 

consistency of the wall materials.

TROUBLESHOOTING & CONSTRUCTION TIPS

SITUATION

LIKELY CAUSE

SOLUTION

Area of voltage 

appears larger than 

actual wire during  

AC SCAN.

Voltage detection can 

spread on drywall by as 

much as 12" (30 cm) on 

each side of the wire.

Narrow the scan detection:  

1. 

Turn scanner off.  

2. 

Turn it on again at the 

edge of where the wire was first detected.  

3.

 Repeat scan.

Difficulty detecting 

metal.

Scanner was calibrated 

over metal object or 

metal object is too deep 

or too small.

• The scanner may have been calibrated over a metal object, reducing 

sensitivity. Try calibrating in another location.
• Scan in both horizontal and vertical directions. Metal sensitivity is increased 

when metal object is parallel to sensor.

Metal object reading 

appears wider than 

actual size.

Scanner sensitivity is 

calibrated too high.

To reduce sensitivity in METAL SCAN Mode, recalibrate scanner over either of 

first two marks (see steps under SCAN FOR METAL).

Display flashes red 

continually at start 

of scan.

Scanner was calibrated 

directly over an area of 

live AC.

Release the Power Button, slide the tool a few inches (5−8 cm) to the left or 

right, and repeat scan.

Electrical wires 

suspected but none 

detected.

Wires are shielded by a 

metal conduit, braided 

wire, or metallic wall 

covering.

Use METAL SCAN Mode to scan for metal, wire, or metal conduit.

Wires deeper than 

2" (50 mm) from the 

surface might not be 

detected.

If there is an outlet switch, turn it to ON position while scanning, but turn OFF 

when working near the wires. Use extra caution if the area has plywood, thick 

wood backing behind drywall, or walls that are thicker than normal. 

Wires may not be live.

Plug a lamp into the outlet and turn it on to test whether wires are live.

Low Battery Indicator 

flashes and scanner 

does not operate.

Low battery.

Install new 9-volt alkaline battery with an extended expiration date.

SpotLite

®

 Pointer

Mode 

Selector 

Switch

Battery  

Door Tab

Target 

Indicaton 

Bars

Ergonomic 

Rubber Grip

Power 

Button

METAL SCAN  

Mode Indicator

Low Battery 

Indicator

Target Indicator

AC SCAN Mode / 

WireWarning

® 

Detection 

Indicator

Figure A

Figure B

Figure C

Figure D

Figure E

BEFORE YOU BEGIN

- Always use new alkaline batteries with an extended expiration date at least 3 years beyond the current date.  

- Do not rely exclusively on the scanner to locate items behind a surface. Use other information to help locate such items 

before penetrating the surface, including construction plans, visible points of entry of pipes and wiring into walls such as 

in a basement, and standard stud-spacing practices.

- Readings should always be consistent and repeatable.

- Zircon scanners are recommended for interior use only.

- Other objects commonly contained in walls, floors, or ceilings are water pipes, gas lines, firestops, and electrical wiring.

- Sensing depth and accuracy can vary depending on scanning environment conditions such as mineral content, moisture, 

texture and consistency of the wall materials.

- Always turn off power when working near electrical wires (except when scanning).

- Due to the proximity of electrical wiring or pipes to the wall surface, caution should always be used when nailing, 

cutting, or drilling in walls, floors, and ceilings that may contain these items.

Visit www.zircon.com for the 

most current instructions.

FCC Part 15 Class B Registration Warning: This device complies  

with Part 15 of FCC Rules. Operation is subject to the following  

two conditions: (1) this device may not cause harmful interference, 

and (2) this device must accept any interference received, including 

interference that may cause undesired operation.

ZirconCorporation

ZirconTV

ZirconTools

 

|

 

ZirconToolPro

ZirconTools

LIMITED 1 YEAR WARRANTY
Zircon Corporation (“Zircon”) warrants to the product 

owner that this product will be free from defects in 

materials and workmanship for one year from the 

original date of purchase. Any defective product 

returned to Zircon within the warranty period to the 

address below, freight prepaid, along with proof of 

purchase, will be repaired or replaced, at Zircon’s 

option. Repair or replacement may be made with a 

new or refurbished product or components, at Zircon’s 

sole discretion. If the returned product is no longer 

available, Zircon may replace the product with a 

similar product of similar function. This warranty is 

limited to the electronic circuitry of the product and 

original case of the product, and specifically excludes 

any damage caused by abuse, modification, handling 

contrary to these instructions, other unreasonable use, 

or neglect. This is your sole and exclusive remedy for 

breach of this Limited Warranty.
This Limited Warranty is in lieu of all other warranties, 

express or implied, and no other representations or 

claims of a similar nature will bind or obligate Zircon. 

Any implied warranties applicable to this product 

that cannot be disclaimed are limited to the one year 

period following its purchase. This Limited Warranty 

does not cover consumable parts, including batteries, 

or software, even if packaged with the product.  

IN NO EVENT WILL ZIRCON BE LIABLE FOR ANY 

SPECIAL, INCIDENTAL OR CONSEQUENTIAL DAMAGES 

RESULTING FROM POSSESSION, USE OR MALFUNCTION 

OF THIS PRODUCT.
Some states do not allow limitations on certain 

implied warranties and/or the limitation on incidental 

or consequential damages, so the above limitations 

and exclusions may not apply to you. This warranty 

gives you specific legal rights, and you may also have 

other rights which vary from state to state. 
Return products for warranty service, freight prepaid 

with proof of purchase (a dated sales receipt) to:
Zircon Corporation, Attn: Returns Department 

1580 Dell Avenue 

Campbell, CA 95008-6992 USA
Be sure to include your name and return address.  

Allow 4–6 weeks for delivery. 
Customer Service: 1-800-245-9265 or 1-408-963-4550 

Monday–Friday, 8:00 a.m.–5:00 p.m. PT 

info@zircon.com • www.zircon.com
©2018 Zircon Corporation • P/N 68969 • Rev D 05/18 
ColorTrip, ElectriScanner, SpotLite, WireWarning,  

and Zircon are registered trademarks or trademarks  

of Zircon Corporation.

ColorTrip

 Display

Summary of Contents for ElectriScanner e60c

Page 1: ...practices Readings should always be consistent and repeatable Zircon scanners are recommended for interior use only Other objects commonly contained in walls floors or ceilings are water pipes gas lines firestops and electrical wiring Sensing depth and accuracy can vary depending on scanning environment conditions such as mineral content moisture texture and consistency of the wall materials Alway...

Page 2: ...expiration date at least 3 years beyond the current date Be sure not to pull on wires when disconnecting an old battery Low Battery Indicator will flash when battery charge is too low for scanner to function properly WARNING Do not rely exclusively on the scanner to locate items behind a surface Use other information to help locate items before penetrating the surface including construction plans ...

Page 3: ...et Indication Bars show on the display Figure C 5 Continue in same direction until bars reduce then reverse direction Mark the spot where the display bars peak Figure D The midpoint between the two marks is the location of the live AC wiring Figure E If the unit indicates live electricity over a large area reduce the sensitivity of the scanner to refine the scanning area and more accurately locate...

Page 4: ...URFACE SCAN FOR METAL Use METAL SCAN to locate ferrous magnetic metal such as structure steel or rebar up to 3 75 mm below the scanned surface or non ferrous non magnetic metal such as copper piping up to 11 2 38 mm scanned surface 1 Set mode to METAL SCAN 2 For maximum sensitivity press and hold Power Button Hold the scanner away from the surface until a short beep confirms calibration is complet...

Page 5: ...ion Wallpaper may need to dry for several weeks after application Freshly painted walls Paint may take a week or longer to dry after application Lath and plaster Use METAL SCAN to locate the nail heads holding wood lath to the studs If the plaster has metal mesh reinforcement the scanner will be unable to detect studs through that material Highly textured walls acoustic ceilings wood flooring subf...

Page 6: ...bind or obligate Zircon Any implied warranties applicable to this product that cannot be disclaimed are limited to the one year period following its purchase This Limited Warranty does not cover consumable parts including batteries or software even if packaged with the product IN NO EVENT WILL ZIRCON BE LIABLE FOR ANY SPECIAL INCIDENTAL OR CONSEQUENTIAL DAMAGES RESULTING FROM POSSESSION USE OR MAL...

Page 7: ... the Power Button slide the tool a few inches 5 8 cm to the left or right and repeat scan Electrical wires suspected but none detected Wires are shielded by a metal conduit braided wire or metallic wall covering Use METAL SCAN Mode to scan for metal wire or metal conduit Wires deeper than 2 50 mm from the surface might not be detected If there is an outlet switch turn it to ON position while scann...

Reviews: