997-532-000-1, Issue 1
March 2006
i
EN54 & ISO 7240 2-8 Zone Conventional Fire Panel - Installation & Configuration Manual
Contents
1
Introduction
1.1
Manual Purpose .............................................. 1
1.2
System Design & Planning .............................. 1
1.2.1 Personel ..................................................... 1
1.3
General ........................................................... 1
1.4
CE Marking ..................................................... 2
1.5
EN54 & ISO 7240 Functions ........................... 3
1.6
Ancillary Functions .......................................... 4
1.7
Related Documents ........................................ 4
1.8
Warnings & Cautions ...................................... 4
2
Installation Guide
2.1
How to Use this Guide .................................... 5
2.2
Pre-installation Check List .............................. 5
2.2.1 Some Panel DO’s and DON’Ts .................. 5
2.3
Transient Protection ........................................ 6
2.4
Product Inspection .......................................... 7
2.4.1 Checking Your Panel for Damage .............. 7
2.4.2 What to do if Your Panel is Damaged .............. 7
2.5
Installation Preparation ................................... 8
2.5.1 Removing the Cover .................................. 8
2.5.2 Back Box Fixing ......................................... 8
2.6
Optional Equipment ........................................ 9
2.6.1 2-Way Relay PCB ...................................... 9
2.6.2 8-Way Relay PCB ...................................... 9
3
Cabling
3.1
Cabling Instructions ...................................... 10
3.1.1 Cable Terminations ................................... 11
3.2
Quality of Cable and of Cable Installation ........... 11
3.3
EMC Considerations ..................................... 12
3.4
Cables for Sounder Circuits .......................... 12
4
Field Devices
4.1
End-of -Line Devices ..................................... 13
5
Panel Electronics
5.1
Main PCB ...................................................... 14
5.2
PSU PCB ...................................................... 15
5.3
Label Inserts ................................................. 15
6
Commissioning
6.1
Introduction ................................................... 16
6.2
Preliminary Checks ....................................... 16
6.3
External Wiring ........................................ 16
6.3.1 Zone Wiring - New Installation ................. 16
6.3.2 Zone Wiring - Retrofit Installation ............. 16
The following markings are used either on
the panel hardware or in the documentation.
They have the following meaning:
WARNING:
Risk of electric shock.
Before working on mains
connections, ensure mains
power supply to the panel
is disconnected.
CAUTION:
Refer to the accompanying
documentation. (When
used in the documentation,
this marking is normally
associated with additional
instructions).
!
EN54
ISO 7240
!
EN54
ISO 7240
CAUTION:
Failure to comply with the
requirements of EN54 (and
ISO 7240) is possible if warning
is ignored. The relevant
clause reference is stated.
CAUTION:
Heat Hazard
Under certain fault
conditions PCB areas
identified by this symbol
may reach high
temperatures.