background image

1. INSTALLING THE BATTERY

Press battery door release in with your finger or a coin and lift up to remove 

door. Connect new 9-volt battery to cable. Place into the compartment 

and press into place. Replace battery door and snap shut.

2. OPERATING TIPS

For optimum scanning results, it is important to properly hold the 

MultiScanner

 

i

520 and move slowly when scanning. The following 

tips will provide more accurate scanning results:

• Grasp the handle with your thumb on one side and your fingers on 

the other side. Make sure your fingertips are resting on or above 

the running board and not touching the surface being scanned or 

the scanning head of the tool.

• Hold the tool straight up and down, parallel to the studs, 

and do not rotate the tool.

• Keep tool flat against the wall and do not rock, tilt, 

 

or press hard when slowly sliding across the surface 

being scanned.

• Avoid placing your other hand, or any other part of your 

body, on the surface being scanned. This will interfere 

with the tool’s performance.

If you’re receiving erratic scanning results, it may be a 

result of humidity, moisture within the wall cavity or 

drywall, or recently applied paint or wallpaper that hasn’t 

fully dried. While the moisture may not always be visible, 

it will interfere with the tool’s sensors. Please allow a few 

days for the wall to dry out.

WORKING WITH DIFFERENT MATERIALS
Wallpaper: 

MultiScanner

 

i

520 functions normally 

on walls covered with wallpaper or fabric, unless the 

materials are metallic foil, contain metallic fibers, or are 

still wet after application. 

Wallpaper may need to dry for 

several weeks after application.

Freshly painted walls:

 May take one week or longer to 

dry after application. If it is difficult to locate a stud in 

STUD SCAN mode on fresh paint, switch to METAL SCAN 

mode to locate nails or drywall screws holding drywall 

to studs.

Lath & plaster:

 Due to irregularities in plaster  

thickness, it is difficult for MultiScanner

 

i

520 to  

locate studs in STUD SCAN mode. Change to METAL 

SCAN mode to locate the nail heads holding wood 

 

lath to the studs. If the plaster has metal mesh 

reinforcement, MultiScanner

™ 

 

i

520 be unable to  

detect through that material.

Extremely textured walls or acoustic ceilings:

  

When scanning a ceiling or wall with an uneven surface, 

place thin cardboard on the surface to be scanned and 

scan over the cardboard in STUD DEEPSCAN

™ 

mode.  

If irregular scanning results are received, switch to METAL 

SCAN mode to locate nails or drywall screws that line up 

vertically where a stud or joist is positioned. 

Wood flooring, subflooring, or gypsum drywall over plywood sheathing:

 Use 

DEEPSCAN

™ 

mode and move the tool slowly. The Signal Strength Indicator may only 

display 1 or 2 bars when the tool locates a stud through thick surfaces.
MultiScanner

 

i

520 cannot scan for wood studs and joists through carpet and padding. 

In problematic situations, try using METAL SCAN to locate nails or screws that may line 

up vertically where a stud or joist is positioned.

Note: Sensing depth and accuracy can vary due to moisture, content of materials, wall 

texture, and paint.

Do not rely exclusively on the detector to locate items behind 

the scanned surface. Use other information sources to help 

locate items before penetrating the surface. Such additional sources include 

construction plans, visible points of entry of pipes and wiring into walls,  

such as in a basement, and in standard 41 and 61 cm stud spacing practices.

3. SELECTING THE MODE

Move selector switch to the desired mode: STUD SCAN for finding wood or metal 

studs; DEEPSCAN

™ 

for scanning walls over 19 mm thick; METAL SCAN for locating 

metal; or AC SCAN for locating live AC wiring.

Unit will remain off if Power button is not pressed.

4. FINDING A STUD

Always

 scan for studs with the scanner placed flat against the wall. Move the  

mode switch to STUD SCAN, place the tool flat against the wall, then press and 

 

hold the Power button. Wait for beep to confirm calibration has completed before 

moving scanner. 

Slowly slide tool across surface. EDGE display 

 

will illuminate, indicating location of the stud edge.

Continue sliding tool. When the center of a stud  

is located, three bars on the Signal Strength Indicator,  

the four Middle bars, CENTER display, and SpotLite

™ 

  

Pointing System will all illuminate and the buzzer  

will sound.

Note: If any bars display on the screen, metal is present. Small targets or targets deep 

within the surface may only illuminate some of the bars and not the center line or audio 

tone. In this case, use the highest indication to determine the metal position.

8. SCANNING IN AC MODE

As with METAL SCAN Mode, AC SCAN Mode has interactive calibration and works in 

the same manner. 
1. 

(Figure A)

 Move mode switch to AC SCAN mode. Press the tool flat against the 

wall, then press and hold the Power button. Wait for the beep to confirm calibration 

has completed before moving the tool. Once calibration has completed, slowly slide 

the scanner across the surface. Mark the location where you get the highest AC 

indication (the most Middle bars on the screen). If it is a strong target, the SpotLite

 

Pointing System will also shine a beam of light and a steady beep will sound. Continue 

in same direction until display bars reduce. Reverse direction and mark the spot where 

the display bars peak from the reversed direction. The midpoint of the two marks is 

the location of the center of the live AC wiring. If the unit indicates live electricity over 

a large area, you can reduce the sensitivity of the tool to refine the scanning area and 

more accurately locate the live AC wiring by following steps 2 and 3 below.

2. 

(Figure B)

 To further pinpoint the location of the live AC wiring, scan the area 

again. Release the Power button and then turn the unit back on, this time starting on 

the wall over one of the previous marks. This will reset the tool to a lower sensitivity 

and narrow the scan area.

3. 

(Figure C)

 Scan in both directions as in Step 2. The area indicated should  

become smaller so you can more precisely identify the location of live AC wires. 

 

This procedure can be repeated to narrow the field even further.

Note: AC SCAN will only detect live (hot) unshielded AC wiring. Please refer to the 

WARNING statement in number 6, WireWarning

 

Detection, for more important details 

and warnings about AC detection.

FCC Part 15 Class B Registration Warning 

This device complies with Part 15 of FCC Rules. Operations subject to the following two conditions:  

(1) this device may not cause harmful interference, and (2) this device must accept any interference received, 

including interference that may cause undesired operation. 

This MultiScanner

 

i

520 OneStep

 

 

features four scanning modes:

• STUD SCAN: Locates the center and edges of wood and metal 

studs up to 19 mm deep

• STUD DEEPSCAN

: Locates the center of wood and metal studs up 

to 38 mm deep

• METAL SCAN: Detects and locates ferrous (magnetic) metal 

 

(such as 13 mm rebar) up to 76 mm deep and 

 

non-ferrous (non-magnetic) metal up to 38 mm deep

• AC SCAN: Detects and locates live unshielded AC wires up to 

 

51 mm deep

WireWarning

 detection automatically detects and alerts of live  

AC wires in STUD SCAN, STUD DEEPSCAN

, and METAL SCAN 

modes. When AC voltage is detected, the AC WireWarning

 

icon  

will be displayed on screen.

Note: This product is intended only for use with an optimum 

voltage range of 110–127 V.

Figure A

Figure B

Figure C

SpotLite

 

Pointing System

Ultra-bright Display

Mode Selector Switch

Battery (back of unit)

Stud Scan Mode Indication

Stud Edge or Center Indication

AC Mode & WireWarning

 

Detection Indication

Middle Bars

Metal Mode Indication

ACT

 (Auto Correcting

 

Technology) Indication

Signal Strength 

Indicator

Running Board

Power Button

In cases of deeper studs (thicker walls), when the center  

of the stud is located only two bars will show on the  

Signal Strength Indicator and only the SpotLite

™ 

Pointing 

System and four Middle bars will illuminate. If you still  

cannot locate a stud, try STUD DEEPSCAN

™ 

mode. In STUD  

DEEPSCAN

™ 

mode, the Stud icon will continuously flash.

5. CALIBRATING THE TOOL IN 

    STUD SCAN/STUD DEEPSCAN

 MODE

MultiScanner

 

i

520 can be calibrated anywhere on the wall. It provisionally monitors 

the subsurface environment 10 times per second and automatically recalibrates, when 

needed, to successfully find the center of studs in one step.

•  Place MultiScanner

 

i

520 against the wall 

before

 pressing the Power button in 

STUD SCAN or STUD DEEPSCAN

 

mode.

•  Once powered on, tool will automatically perform all calibrations. The LCD will 

display all icons until calibration is complete. Upon completion of calibration, the 

SpotLite

®

 

Pointing System and buzzer will momentarily activate and the tool will 

begin continuous measurements. Continue to press Power button down and keep 

the tool flat against the wall and begin scanning.

Note: It is important to wait for calibration to complete (1–2 seconds) before moving 

the scanner. 

ACT

 (Auto Correcting Technology)

 

During scanning, the tool will 

automatically recalibrate itself when 

needed. This recalibration is transparent 

and no indication is made. If an arrow 

icon illuminates, the tool calibrated near 

or over a stud and then moved away. 

The arrow indicates the direction of the 

missed stud.

6. WIREWARNING

 

DETECTION

Zircon's WireWarning

™ 

detection feature works continuously in in STUD SCAN, 

 

STUD DEEPSCAN

, and METAL SCAN modes. When live AC voltage is detected, 

 

the AC detection warning indicator will appear in the display. If scanning begins over 

 

a live AC wire, the AC indicator will flash continuously. Use extreme caution under 

 

these circumstances or whenever live AC wiring is present.

Electrical field locators may not detect live AC wires if wires 

are more than 51 mm from the scanned surface, encased in 

conduit, present behind a plywood shear wall or metallic wall covering, or if 

moisture is present in the environment or scanned surface. 

DO NOT ASSUME THERE ARE NO LIVE ELECTRICAL WIRES IN THE 

WALL. DO NOT TAKE ACTIONS THAT COULD BE DANGEROUS 

IF THE WALL CONTAINS A LIVE ELECTRICAL WIRE. ALWAYS TURN OFF THE 

ELECTRICAL POWER, GAS, AND WATER SUPPLIES BEFORE PENETRATING A 

SURFACE. FAILURE TO FOLLOW THESE INSTRUCTIONS MAY RESULT IN ELECTRIC 

SHOCK, FIRE, AND/OR SERIOUS INJURY OR PROPERTY DAMAGE.

Always turn off power when working near electrical wires.

7. SCANNING IN METAL MODE

Note: When scanning for studs, use STUD SCAN mode (or Stud DEEPSCAN

 mode on 

thicker walls) to quickly locate the center and edges. Use METAL SCAN to determine 

if the previous reading in STUD SCAN was a wood stud, metal stud, or pipe. In METAL 

SCAN, only metal drywall screws will be found in wood studs, while metal will be 

indicated everywhere on a metal stud or pipe.

METAL SCAN has interactive calibration to adjust to its sensitivity to metal, which 

can be used to find the precise location of metal objects in walls, floors, and ceilings. 

Maximum sensitivity is ideal for quickly finding the approximate location 

 

of metal. However, sensitivity can be reduced by calibrating the tool closer to metal. 

With reduced sensitivity, the area where metal is indicated will be smaller. But in  

both cases, the metal target is in the center of the area where the tool indicates metal 

is present.

1. Move mode switch to METAL SCAN mode. For maximum metal sensitivity, turn the 

tool on in the air by pressing and holding the Power button. This will ensure that it 

calibrates away from any metal objects. 

(The tool can only be calibrated  

off the wall in METAL SCAN mode.)

2. 

(Figure A)

 While holding the Power button, press the tool flat against the 

wall and slowly slide the scanner across the surface. Mark the point where you  

get the highest metal indication (the most Middle bars on the screen). If it is a  

strong target, the SpotLite

™ 

Pointing System will also shine a beam of light and a 

steady beep will sound. Continue in the same direction until display bars reduce. 

Reverse direction and mark the spot where the display bars peak from the  

reversed direction. The midpoint of the two marks is the location of the center  

of the metal object.
If the unit indicates metal over a large area, you can refine the scanning area to  

more accurately locate the metal target by following steps 3 and 4 below.
3. 

(Figure B)

 To further pinpoint the location of the metal target, scan the area again. 

Release the Power button and then turn the unit back on, this time starting on the 

wall over one of the previous marks. This will reset the tool to a lower sensitivity and 

narrow the scan area. 

4. 

(Figure C)

 To continue to reduce sensitivity and further refine the scanning area, 

repeat step 3. This procedure can be repeated multiple times to narrow the field 

 

even further.

WARNING

WARNING

MultiScanner

 

i

520 OneStep

Multifunction Wall Scanner

Detects other objects besides studs  

in STUD SCAN mode. 

 

Finds more targets than there  

should be.

• Electrical wiring and metal/plastic pipes may be 

 

near or touching back surface of wall.

• Scan the area in METAL SCAN and AC SCAN to determine if metal or hot AC is present.

• Check for other studs equally spaced to either side 31, 41, or 61 cm apart or for the same stud at several places 

directly above or below the first scan area.

• A stud reading would measure approximately 38 mm apart from each edge; anything larger or smaller is most 

likely not a stud if not near a door or window.

9. HELPFUL HINTS

 

(See also number 2, Operating Tips)

 

Situation

Probable Cause

Solution

LIMITED 1 YEAR WARRANTY

Zircon Corporation, (“Zircon”) warrants this product to be free from defects in materials and workmanship  

for one years from the date of purchase. Any in-warranty defective product returned to Zircon*, freight prepaid 

with proof of purchase date and $5.00 to cover postage and handling, will be repaired or replaced at Zircon’s 

option. This warranty is limited to the electronic circuitry and original case of the product and specifically 

excludes damage caused by abuse, unreasonable use or neglect. This warranty is in lieu of all other warranties, 

express or implied, and no other representations or claims of any nature shall bind or obligate Zircon. 

 

Any implied warranties applicable to this product are limited to the one year period following its purchase. 

IN NO EVENT WILL ZIRCON BE LIABLE FOR ANY SPECIAL, INCIDENTAL OR CONSEQUENTIAL DAMAGES 

RESULTING FROM POSSESSION, USE OR MALFUNCTION OF THIS PRODUCT.

In accordance with government regulations, you are advised that: (i) some states do not allow limitations  

on how long an implied warranty lasts and/or the exclusion or limitation of incidental or consequential 

damages, so the above limitations and/or exclusions may not apply to you, and further (ii) this warranty 

 

gives you specific legal rights and you may also have other rights which vary from state to state.

Return product freight prepaid with proof of purchase date (dated sales receipt) and $5.00 to cover postage  

and handling, to:
Zircon Corporation 

*Attn: Returns Department

 

1580 Dell Avenue

 

Campbell, CA 95008-6918 USA

Be sure to include your name and return address. Out of warranty service and repair, where proof of purchase  

is not provided, shall be returned with repairs charged C.O.D. Allow 4 to 6 weeks for delivery.
Customer Service, 1-800-245-9265 or 1-408-963-4550

 

Monday–Friday, 8:00 a.m. to 5:00 p.m. PDT

 

www.zircon.com • info@zircon.com

©2012 Zircon Corporation • P/N 62239 Rev C 04/12

Visit www.zircon.com/support for the most current instructions.

ACT, CenterVision, DeepScan, MultiScanner, OneStep, SpotLite, WireWarning, and Zircon are registered trademarks or trademarks of Zircon Corporation.

Constant readings of studs near 

windows and doors.

• Double and triple studs are usually found around 

 

doors and windows. Solid headers are above them.

• Detect outer edges so you know where to begin.

You suspect electrical wires, but do not 

detect any.

Unit flashes and beeps 6 times, 

 

then LCD display remains blank with 

 

backlit screen on.

• Low battery.

• Replace with new battery.

• Wires are shielded by metal conduit, a braided 

 

wire layer, or metallic wall covering.

• Wires deeper than 51 mm from surface might 

 

not be detected.

• Wires may not be live.

• Try METAL SCAN mode to see if you can find metal, wire, or metal conduit.

• Try turning on switches to outlet.

• Try plugging a lamp into outlet and turning on switch.

Image of metal object appears wider 

than actual size.

• Metal has greater density than wood.

• To reduce sensitivity, recalibrate MultiScanner

 

i

520 over either of first two marks (Metal mode only).

Difficulty detecting metal.

• Tool calibrated over metal object.

• Metal targets too deep or small.

• The scanner may have been calibrated over a metal object, reducing sensitivity. Try calibrating in another location.

• Scan in both horizontal and vertical directions. Metal sensitivity is increased when metal object is parallel to sensor, 

located under Zircon logo.

Area of voltage appears much larger 

 

than actual wire (AC only).

• Voltage detection can spread on drywall as much 

 

as 31 cm laterally from each side of an actual 

electrical wire.

• To narrow detection, turn unit off and on again at the edge of where wire was first detected and scan again.

WARNING

ZirconCorporation

ZirconTV

Summary of Contents for MultiScanner i520 OneStep

Page 1: ...scanned or the scanning head of the tool This MultiScanner i520 OneStep features four scanning modes STUD SCAN Locates the center and edges of wood and metal studs up to 19 mm deep STUD DEEPSCAN Locates the center of wood and metal studs up to 38 mm deep METAL SCAN Detects and locates ferrous magnetic metal such as 13 mm rebar up to 76 mm deep and non ferrous non magnetic metal up to 38 mm deep AC...

Page 2: ...tor Switch Battery back of unit Stud Scan Mode Indication Stud Edge or Center Indication AC Mode WireWarning Detection Indication Middle Bars Metal Mode Indication ACT Auto Correcting Technology Indication Signal Strength Indicator Running Board Power Button ...

Page 3: ...ntain metallic fibers or are still wet after application Wallpaper may need to dry for several weeks after application Freshly painted walls May take one week or longer to dry after application If it is difficult to locate a stud in STUD SCAN mode on fresh paint switch to METAL SCAN mode to locate nails or drywall screws holding drywall to studs Lath plaster Due to irregularities in plaster thickn...

Page 4: ...s of entry of pipes and wiring into walls such as in a basement and in standard 41 and 61 cm stud spacing practices 3 SELECTING THE MODE Move selector switch to the desired mode STUD SCAN for finding wood or metal studs DEEPSCAN for scanning walls over 19 mm thick METAL SCAN for locating metal or AC SCAN for locating live AC wiring Unit will remain off if Power button is not pressed 4 FINDING A ST...

Page 5: ...nuous measurements Continue to press Power button down and keep the tool flat against the wall and begin scanning Note It is important to wait for calibration to complete 1 2 seconds before moving the scanner ACT Auto Correcting Technology During scanning the tool will automatically recalibrate itself when needed This recalibration is transparent and no indication is made If an arrow icon illumina...

Page 6: ...ol indicates metal is present 1 Move mode switch to METAL SCAN mode For maximum metal sensitivity turn the tool on in the air by pressing and holding the Power button This will ensure that it calibrates away from any metal objects The tool can only be calibrated off the wall in METAL SCAN mode 2 Figure A While holding the Power button press the tool flat against the wall and slowly slide the scann...

Page 7: ...nter of the live AC wiring If the unit indicates live electricity over a large area you can reduce the sensitivity of the tool to refine the scanning area and more accurately locate the live AC wiring by following steps 2 and 3 below 2 Figure B To further pinpoint the location of the live AC wiring scan the area again Release the Power button and then turn the unit back on this time starting on th...

Page 8: ...ales receipt and 5 00 to cover postage and handling to Zircon Corporation Attn Returns Department 1580 Dell Avenue Campbell CA 95008 6918 USA Be sure to include your name and return address Out of warranty service and repair where proof of purchase is not provided shall be returned with repairs charged C O D Allow 4 to 6 weeks for delivery Customer Service 1 800 245 9265 or 1 408 963 4550 Monday F...

Reviews: