BG500 Series Barrier Gate
User Manual
P a g e
|
20
Copyright©2022 ZKTECO CO., LTD. All rights reserved.
Set Delay for Automatic Closing after Opening the Boom
Long press the
Menu
button, then press +/- to select the L20 parameter, and then press
the
Menu
to set the parameter value after selection. At this time, the display will be 000
i.e., in the disabled state. Set the delay value as per the requirements. Finally, press
Enter
to exit the menu. For example, if it is set to "005", the machine will automatically close
after 5 seconds after opening the barrier.