BGM1000 Series Barrier Gate (APP Version) User Manual
P a g e
| 24
Copyright©2023 ZKTECO CO., LTD. All rights reserved.
Remote Control Pairing and Unpairing
8.4
8.4.1
Pairing
Long press
[Menu/save]
, then press
[Stop/
▼
]
flip down
to
[15EXXX]
. Press
[+/-]
to set the
parameter value. At this time, the LED display value is "
15EX0X
", and then press any
button on the remote control until you hear a beep sound from the Mainboard, it means
the pairing is successful, and then press
[Menu/save]
exit the menu.
8.4.2
Unpairing
Long press
[Menu/save]
, then press
[Stop/
▼
]
flip down
to
[15EXXX]
. Press
[+/-]
to set the
parameter value, and then set the parameter value to "
15E200
". Press
[Menu/save]
to
save the setting and that all the remote controls have been deleted.
Set Delay for Automatic Closing after Opening the
8.5
Boom Arm
Long press the
[Menu/save]
button, then press
[Stop/
▼
]
flip down
to
[11EXXX]
parameter, and then press the
[+/-]
to set the parameter value after selection. Set the delay
value as per the requirements. Finally, press
[Menu/save]
to exit the menu. For example, if
it is set to "
11E007
", the device will automatically close after 7 seconds after opening the
barrier gate.