FBL200/300 Flap Barrier
User Manual
P a g e
| 16
2)
If there is a voltage on the 24 V terminal on the mainboard, check whether the fuse tube is normal.
If the fuse tube is damaged, replace the fuse tube. If the fuse tube is normal, it indicates that the
mainboard is damaged and replace the mainboard.
3.
The gate is not reset after opening or reset immediately after opening to the position
When the pedestrian passes, the gate does not resume immediately, and the gate is closed after a
certain time delay, indicating that the outgoing infrared works abnormally.
Detection method: first detect the cylindrical photoelectric switch and whether it is connected; when
there is signal output, the left or right infrared indicator light on the mainboard will turn on,
otherwise the mainboard will be damaged; check whether the parameters of the mainboard are
set with memory.
After the gate is opened, when the pedestrian enters the channel, the gate will reset immediately,
indicating that the left and right infrared are inversely connected. Check the connection with the
mainboard.
4.
The gate is not open after power failure
1)
Test the voltage of the dry battery (not lower than dc9v).
2)
Check whether the circuit is loose or desoldered, and detect the voltage output at both ends of
the battery terminal (not lower than dc9v), otherwise the control board will be damaged.
5.
The swing arm is not limited after power failure and reversed after power on
1)
Test the voltage of dry battery (not lower than dc9v).
2)
Detect the photoelectric switch and main board of the left and right switch in place respectively;
(see 1)
3)
The swing arm is reversed and the motor line is reversed.
6.
When it is used online, the cylindrical photoelectric switch will be opened
The machine has been switched to infrared switch on mode. Enter the menu to change the working
mode of the brake to swipe the card.
7.
The two gates are not synchronized when they are on-line
Check whether the online line is loose or loose, and whether the line sequence is one-to-one
corresponding.
8.
After swiping the card to open the gate, the gate shall not be opened until the access control
panel is closed