32 G3 Pro User Manual
7.2 Attendance Parameters
Tap
Attendance
on the
System
interface.
Menu Item
Description
Duplicate Punch
Period (m)
Within a set time period (unit: minutes), the duplicated attendance logs will not be reserved
(value ranges from 1 to 999999 minutes).
Camera Mode
To set whether to take and save photos in verification; applicable to all users. The following 5
modes are included:
No Photo:
No photo is taken in user verification.
Take photo, no save:
Photo is taken but not saved in verification.
Take photo and save:
Photo is taken and saved in verification.
Save on successful verification:
Photois taken and saved in successful verification.
Save on failed verification:
Photo is taken and saved in failed verification.
Display User Photo
To set user photo to be displayed when a user passes verification. Turn it
[ON]
to display user
photo and
[OFF]
to disable it.
Alphanumeric User
ID
Whether to support letters in employee ID.
Attendance Log
Alert
When the remaining storage is smaller than the set value, the device will automatically alert
users to the remaining storage information. It can be disabled or set to a value ranged from 1
to 9999.
Cyclic Delete ATT
Data
The number of attendance logs allowed to be deleted in one time when the maximum storage
is attained. It can be disabled or set to a value ranged from 1 to 999.
Cyclic Delete ATT
Photo
The number of attendance photos allowed to be deleted in one time when the maximum
storage is attained. It can be disabled or set to a value ranged from 1 to 99.
Confirm Screen
Delay(s)
The display of the verification information interface after verification. Value ranges from 1 to 9
seconds.
7. Select a daylight saving mode.
8. Set when to start and end the daylight
saving time.