33
Lock
: This parameter is used to set the duration from successful matching
to unlocking. Select
Lock
and press
OK
to display the Lock
interface. Press ▲/▼ to select a value. Press
ESC
to exit current
interface and save your settings. For this parameter, its unit of
quantity is 1 second and value range is 3–15, that is, 3–15 seconds.
Note:
The unit of quantity and the maximum value of this parameter here are
standard configurations. If you need larger parameter values, please consult
our commercial representatives or pre-sales technical support engineers.
Verify Mode
: Press
OK
to display the Verify Mode interface, and press ▲/▼ to
select a value. There are three optional values 0, 1, and 2 that
represent different matching modes respectively, and the default
value is 1.
Verify Mode 0: Only the administrator can open the lock, while the unlocking
function is disabled for ordinary users.
Verify Mode 1: This is a default matching mode. Users can open the lock by
successfully matching their fingerprints only once.
Verify Mode 2: This is a dual verification mode. The administrator can open the
lock by successfully matching his/her fingerprint only once, but an
ordinary user has to pass the verification in any two matching
modes by using the same ID.
Normal Open
: Press
OK
to display the Normal Open interface, and press ▲/▼ to
select
Yes
or
No
. If you select
Yes
, a prompt will be displayed after
unlocking, inquiring whether you desire to select
Normal Open
. If
you press
OK
, the system will prompt you that the NO function is
enabled and then power off automatically and immediately. The
Normal Open interface is shown as follows: