(
II
)
Does not share power with the lock:
-
+
DC12V
+
NO
LOCK
+
-
NC
LOCK
(6)
Fix
the
device
to
the back cover.
-
①:
‘I’: device output current, ‘U
LOCK
’: lock voltage,’ I
LOCK
’: lock current.
-
FR 107
+
-
FR 107
+12V
GND
NC
NO
GND
COM
AL+
AL-
SEN
BUT
485+
485-
-
+
DC12V
+
-
+
-
FR 107
+12V
GND
NC
NO
GND
COM
AL+
AL-
SEN
BUT
485+
485-
-
+
DC12V
+12V
GND
NC
NO
GND
COM
AL+
AL-
SEN
BUT
485+
485-
+
-
-
+
DC Power
+12V
GND
NC
NO
GND
COM
AL+
AL-
SEN
BUT
485+
485-
-
+
DC12V
-
+
DC Power
+
-
FR 107
+
Installation Guide
1.Equipment
Installation
2. Structure and Function
3
.
Lock
Connection
4
.
Connected
with
Other
Parts:
5
.
Connected with
Power:
(1)
Post the
mounting template on the wall.
Drill the holes according to the marks on the
template (holes for screw and wiring).
(2)
Remove
the
screw
on
the
bottom of device.
(3)
Take away the back cover and
waterproof pad.
(5)
Set
the device to the fixed waterproof pad.
(4)
Fix the back cover and waterproof pad on the
RS485
TCP/IP
RS232
/
RS485
门锁
Card
Reader Exit Button
①
②
③
④
⑤
⑥
Alarm
RS485
TCP/IP
Converter
Lock
Door Sensor
①
②
③
④
⑤
⑥
(1)
T
he
system
supports
NO LOCK
and
NC LOCK. For example the NO LOCK (normally open at power on) is connected with
’NO’ terminal, and the NC LOCK is connected with ‘NC’ terminal.
(
I
)
Share power with the lock:
U
LOCK
=12V,
I-I
LOCK
>1A
…… ①
And
the
lock is
near
to
the
device.
Device
share
power
with the lock
:
NC LOCK
NO LOCK
Device
does
not
share
power
with the lock
:
A.
=12V I-
≤
1A;
U
LOCK
I
LOCK
B
≠
12V;
. U
LOCK
C. The
lock is far apart from the
device.
-
+
Alarm
Alarm
Power
-
+
DC12V
Exit
Button
Door
Sensor
GND
+12V
Input DC 12V, 500mA (50mA standby)
Positive is connected with ‘+12V’, negative is connected
with ’GND’ (
do not reverse the polarities
).
Voltage output
≤
DC 12V for Alarm
NC
NO
GND
COM
AL+
AL-
SEN
BUT
485+
485-
!
Warning: No operating with power on!
(1)If a registered user verified, the device will export the
signal to unlock the door.
Access Control System Function:
(2)Door sensor will detect the on-off state. If the door is
unexpected opened or improperly closed, the alarm
signal (digital value) will be triggered.
(3)If the device being illegally removed, the device will
export alarm signal.
(4)External card reader is supported.
(5)External exit button is supported; it is convenient to
open the door inside.
(6)Supports RS485, TCP/IP modes to connect with PC.
One PC can manage multiple devices.
(2) When the Electrical Lock is connected to the Access Control System, you need to parallel one FR107 diode (equipped
in the package) to prevent the self-inductance EMF affect the system, do not reverse the polarities.
wall according to the mounting paper.
EXIT
EXIT
Mounting Paper(only for your reference)
line hole
10
11
12
13
Version: 1.1
Date: Dec. 2010