6.7.5 Access control parameter
Through the [Access] menu, you can set the parameters of the
electronic locks and related access control devices.
Lock Delay
: Indicates the duration for the device to place the
electric lock in open state. (Value scope: 1-10 seconds)
Door Sensor Delay
: Indicates the delay for checking the door
sensor after the door is opened. If door sensor state is
inconsistent with the normal state set by the door sensor switch,
an alarm will be triggered, and this period of time is regarded as
the “door sensor delay”. (Value scope: 1-99 seconds)
Door Sensor Mode
: Includes the None, Normally Open (NO), and Normally Closed
(NC) modes. “None” indicates that the door sensor switch is not used. “NO” indicates
that the door sensor is open in the normal state.
“NC” indicates that the door sensor is
closed in the normal state.
Alarm Delay
: Indicates the duration from the detection of the door sensor exception to
the generation of alarm signal. (Value scope: 1-99 seconds)
Failure Alarm Threshold:
When the failed press times reach the set times, alarm
signal will come out (effective value: 1-9 times).
NC Time Zone:
Set time zone for access control NC. Nobody can unlock during this
time zone.
NO Time Zone:
Set time zone for access control NO. The lock is always in valid state
during this time zone.
Valid in Holiday:
Define time zone for NO or NC. Whether the time zone set in holiday
time zone is valid.
Notice
:
1. If the Time Zone of normally open or normally closed has been set, please switch
door sensor to no, otherwise it will produce alarm signal during Normal close Time Zone
or Normal open Time Zone.