MultiBio700- User Manual
eSSL Pvt. Ltd.
Page 60
2. If the normally open or normally closed Time Zone is not defined yet by the time, the
equipment will prompt that you to define the Time Zone, and transfer you to the Time
Zone interface to add.
6.7.6 Duress Alarm Parameters
There are duress alarm parameters setting in the device. When
an employee comes across a duress situation, he can use the
set duress alarm mode to verify. The device will open the door
as usual, but the alarm signal will be sent to the alarm.
1: 1 Trigger:
if select “Yes”, when user use 1: 1 match mode,
alarm signal will come out. Or there is no alarm signal.
1: N Trigger:
if select “Yes”, when user use 1: N match mode,
alarm signal will come out. Or there is no alarm signal.
Password Trigger:
If select
“Yes”, when a user use password
verification mode, alarm signal will come out. Or there is no
alarm signal.
Alarm Delay:
After duress alarm gets started, the alarm signal will not output directly. It
can be defined. After the set time period, the alarm signal will be generated
automatically (0-255 seconds).
6.7.7 Anti-Pass back setting
Set the device Anti-Pass back function.
APB Direction:
There are four options: None, APB-Out, APB-
In, APB-Out/In.
Device Status:
There are three options: Exit Control, Entry
Control and None.
For Anti-Pass back function, please refer to Appendix 5 Anti-
Pass back.
Anti-Pass back setting operation:
(1) Enter Anti-Pass back setting interface, press the key to edit