6
4.
Opening mode setting
1)
Bi-direction swiping card
2)
Left direction swiping card
3)
Right direction swiping card
4)
Bi-directional prohibition
Press ''ENT'' key to modify, press “UP/DOWN” to select opening mode, press ''ESC'' to exit.
The default value is Bi-direction swiping card.
5.
Min speed compensation
Adjustable range from 0 to 20.
Press ''ENT'' key to modify, press “UP/DOWN” to select compensation, press ''ESC'' to exit.
The default value is 0.
6.
Delay closing gate time
Adjustable range from 2 to 10.
After pedestrian passes through the last infrared sensor, the gates will keep opening the time
what you set, then close immediately.
Press ''ENT'' key to modify, press “UP/DOWN” to select delay closing gate time, press ''ESC'' to exit,
default value is 5 seconds.
7.
Brake starting angle
Adjustable range from 3 to 10 degrees.
Press ''ENT'' key to modify, press “UP/DOWN” to select brake angle, press ''ESC'' to exit.
The default value is 3 degrees.
8.
Unlock brake method.
About the method of unlocking, it uses delay release. The time of the delay is affected by the
times of lock. The first lock takes 2s, second lock takes 2s, third lock takes 4s, and then it's all 4s. In
this process, if the swing arm is back where it should have been before, it will reset the time.
9.
Firefighting signal setting
1)
Open
2)
Close
Press ''ENT'' key to modify, press “UP/DOWN” to select fighting signal, press ''ESC'' to exit.
The default value is open; it is required firefighting device connection with fire port.
10.
System working mode
1)
Work mode
2)
Auto test
3)
System initialization
Press ''ENT'' key to modify, press “UP/DOWN” to select system working mode, press ''ESC'' to exit,
default value is work mode.
11.
Volume setting
1)
Adjustable range from 1 to 16, default value is 5.
2)
Close sound
Press ''ENT'' key to modify, press “UP/DOWN” to select volume level, press ''ESC'' to exit.
The default value is 5.