9.
Right Gate Closing Deceleration Distance(09EXXX)
The larger the number, the longer the deceleration time and the more stable the swing arm operation.
The Right Gate Closing Deceleration Distance value can be set between 10 to 25 and the default value
is 16.
10.
Gate Closing Delay Time(10EXXX)
The Gate Closing Delay Time value can be set between 2 to 60 seconds and the default value is 5s.
11.
Clutch Start Angle(11EXXX)
Set angle at which clutch starts and the valid value of Clutch Start Angle can be set between 1-10. The
default value is 1.
12.
Clutch Unlock Mode(12EXXX)
The different Clutch Unlock Modes are as follows:
(12E000) Delayed unlock
(12E001) Swipe to unlock (default)
13.
Fire Opening Direction(13EXXX)
The different Fire Opening Directions are as follows: -
(13E000) Right open (default)
(13E001) Left open
(13E002) Closed
14.
Volume Setting(14EXXX)
Adjust the volume of the device as required. The larger the number, the louder the sound. The valid
value of Volume Setting lies between 0-30 and the default value is 8.
15.
Alarm Tone Setting(15EXXX)
(15E000) Closed
(15E001) Open (default)
16.
In/Out Voice Exchange(16EXXX)
(16E000) Right in, left out (default)
(16E001) Right out, left in
17.
Anti-crush Setting(17EXXX)
(17E000) Stop anti-crush (default)
(17E001) Close