Chapter 4 Common failure analysis
Number
Failure phenomena
Analysis and solution
1
Direction indicator no
response or indication is not
correct.
Check whether the connection to the roof
lamp is correct or not.
2
After swipe the card there is
only a swing arm action.
Check the type setting and the 6 core
connection line of main and auxiliary machine.
3
Barrier opens after a long
time without closing.
Check whether the time of the opening is too
long.
4
Swing the arm swing at zero
position.
This situation may be caused by the thirteenth
sets of the menu is too large. to decrease the
value of the thirteenth items may solve the
problems.
5
"Serious malfunctions.
Pendulum rod rotation is out
of preset range,please do
zero correction".
User needs to correct the zero position,left
open position and right open position in
seventh items.