Connect the online cables and perform the power-on test. Wait for 10 seconds for the turnstile to 
complete  the  self-test  program.  At  the  same  time,  check  if  the  indicators  work  properly.  If 
everything works €ne, you can tighten the screws and €x the device. If an exception occurs, please 
contact your vendor.

6.

It is recommended that a warning line be marked on the ground after installing the device, so as 
to prompt the pedestrian to stand behind the warning line when swiping the card. As shown in 
Figure 4-4: 

7.

Wa

rningLine

Wa

rningLine

Figure 4-4

Summary of Contents for SBTL9000 Series

Page 1: ...llation Guide SBTL9000 Series Version 1 0 Due to regular upgrades of systems and products ZKTeco could not guarantee exact consistency between the actual product and the written information in this ma...

Page 2: ...any failures caused by long time operations 4 1 1 Installation Requirements The installation position of the swing barrier turnstile depends on its size A distance of 100mm between the swing barrier t...

Page 3: ...separately to easily distinguish strong and weak power Please invite professional personnel to complete the wiring The device must be connected to the ground 4 Thread the connection wire of the devic...

Page 4: ...e centre of the stand and the edge of the chassis base on the ground according to the sizes as shown on the Figure 4 1 1 2 3 Drill the holes with 14 and embed M12 anchor screws or expansion screws As...

Page 5: ...able power When installing the swing barrier turnstile the user only needs to connect it to the corresponding ports Note that the PVC conduits are laid 100mm under the ground with the height of the ex...

Page 6: ...erly If everything works ne you can tighten the screws and x the device If an exception occurs please contact your vendor 6 It is recommended that a warning line be marked on the ground after installi...

Page 7: ...DI4 DI3 DI2 DI1 COM SW1 SW2 SW3 SW4 1 3 5 6 4 2 J10 J11 J9 J6 H2 LED LED LED WD0 WD1 GLED BEEP 12V GND 12V GND 485 485 GND GND 24V GND K1 K1 CL 485 485 BEEP GLED WD1 12V WD0 TFT 19 LCD 5V IR2 IR1 IR3...

Page 8: ...ZKTeco Industrial Park No 32 Industrial Road Tangxia Town Dongguan China Phone 86 769 82109991 Fax 86 755 89602394 www zkteco com...