signal to the master control board until the pedestrian passes completely through the 
passage. 

5.

 

If the pedestrian enters the passage but forgets to flash the card, or if the card held by the 
pedestrian is invalid, the system will prompt an audible alarm to stop  and retreat the 
pedestrian from the passage. The pedestrian can pass through the passage only after a valid 
card is read by the card reader. 

 

System Composition 

1.5

The single-lane management system is composed of two single-core swing barriers. The multi-lane 
management system is composed of two single-core barriers and multiple dual-core barriers. 

Working modes of the system 

To make the product more versatile, this system provides multiple working modes  for  the user, 
including Normal working mode, Normally open mode, Normally close mode and Testing mode. 

Normal Working Mode:

 In this working mode, the turnstile works normally. 

Normal Open Mode:

 In this working mode, the turnstile is always open. 

Normal Close Mode:

 In this working mode, the turnstile is always closed. 

Testing Mode

: In this working mode, the turnstile performs Power-on Self-Test. 

After supplying power to the device, the LCD screen on control board will display a default state, 
which displays current work mode. 

 

Technical Specifications 

1.6

Feature 

Specification 

Power Requirements 

AC 100 to 120V/200 to 240V, 50/60Hz 

Working Temperature 

-28°C to 60°C 

Working Humidity 

20% to 95% (Non-condensing) 

Working Environment 

Indoor 

Max. Speed of Throughput  

35 people per minute 

Lane Width (mm) 

780 

Infrared Sensor  

12 pairs 

Dimension (mm) 

L=1738, W=142, H=1080 

Summary of Contents for SBTL9000 Series

Page 1: ...d the instructions carefully before operation Follow these instructions to ensure that the product is functioning properly The images shown in this manual are for illustrative purposes only For furthe...

Page 2: ...h the design and that the said personnel have received thorough training in operating and maintaining the machine unit equipment It is further essential for the safe operation of the machine unit equi...

Page 3: ...hine unit equipment and such amendments shall not give any right to claim any compensation or damages under any circumstances ZKTeco shall in no way be responsible I in case the machine unit equipment...

Page 4: ...ent research and development of biometric verification procedures and the productization of biometric verification SDK which was initially widely applied in PC security and identity authentication fie...

Page 5: ...scription Button or key names for devices For example press OK Window names menu items data table and field names are inside square brackets For example pop up the New User window Multi level menus ar...

Page 6: ...ATION REQUIREMENTS 11 2 1 INSTALLATION POSITION 11 2 2 CABLES INSTALLATION AND FIXING 12 2 3 3 MENU INTRODUCTION 14 PASSAGE SETTINGS 14 3 1 3 1 1 GATE SYSTEM SETTINGS 14 3 1 2 GATE FUNCTION SETTINGS 1...

Page 7: ...sitively recognizing a user s valid access card or fingerprint its barriers swing automatically thus allowing users passage to the secured side Chassis Design and Dimensions 1 1 The SBTL9000 Series co...

Page 8: ...SBTL9000 Series User Manual P a g e 7 Copyright 2021 ZKTECO CO LTD All rights reserved Figure 1 1...

Page 9: ...ays the pedestrian passage path and directs them to pass through the lane in a safe and orderly manner Alarm The alarm gives an alarm voice if the system detects any unauthorized entry to the passage...

Page 10: ...m To make the product more versatile this system provides multiple working modes for the user including Normal working mode Normally open mode Normally close mode and Testing mode Normal Working Mode...

Page 11: ...rights reserved Dimension with Packing mm L 1850 W 400 H 1130 Cabinet Material Aluminium Alloy Lid Material Aluminium Alloy Barrier Material Acrylic Barrier Movement Swing Emergency Mode Supports Sec...

Page 12: ...check if the connection is done correctly at the connecting points of the ground wire at the connector assemblies and wiring points of the circuits as well as at each movable part of the swing barrie...

Page 13: ...and its master and slave are connected by an 8 core cable signal and a 2 core cable power When installing the swing barrier turnstile the user only needs to connect it to the corresponding ports Note...

Page 14: ...anchor bolts or expansion bolts Place the swing barrier turnstile according to the sizes and positions as shown in the figure before installation and fixing Connect the online cables and perform the...

Page 15: ...tting to set the Gate System These functions are available in Gate System Settings Motor Driver Board Type The motor drive type is automatically matched and subitems cannot be modified as an informati...

Page 16: ...evice and the valid value is 1 to 65535 Ambient Light Settings Control the blue LED light on the gate Offline Using Enable or disable offline using as per the requirement Clear Running Times Clears al...

Page 17: ...n an unauthorized way and the clutch is locked automatically It can be set as Automatic release or Authorized release Anti pinch Area Setting If a person object is detected in the anti pinch area the...

Page 18: ...e refers to the period of time from opening to closing once the turnstile receives an open signal You can set the unattended time or Open Duration Time with a valid value of 2 to 60 seconds Gate Closi...

Page 19: ...r Clear the alarm counter 3 1 3 External Device Information You can enable disable the direction infrared function to manage the external devices States Description ON When enable it will display the...

Page 20: ...erminal 3 2 Reset USB Slot Ethernet POE Interface Antenna AUX IN 24V DC Power Supply Wiegand Reader 1 RS 485 EXT RS485 Status Indicator Exit or entry status indicator 12V DC Power Supply FACP_SIGNAL S...

Page 21: ...SBTL9000 Series User Manual P a g e 20 Copyright 2021 ZKTECO CO LTD All rights reserved...

Page 22: ...evice IP address and Gateway Note The IP address should be able to communicate with the ZKBioSecurity server preferably in the same network segment with the server address 2 On the Main Menu interface...

Page 23: ...rights reserved 5 LCD Screen Settings The display of the LCD screen can be set through ZKBioSecurity software including the import replacement of playing videos delete or replace the page background a...

Page 24: ...erved Click Entrance Control Device Management Device Device Control to set the LCD screen Set the LCD Screen Display 5 1 To set the LCD screen display take the pixel 360 1920 as a template You can se...

Page 25: ...ideo area occupies 1 3 of the entire LCD screen B Area It is used for setting the count display The counting icon is in jpg format and the count area occupies 2 9 of the entire LCD screen C Area It is...

Page 26: ...mooth movement Power Supply Maintenance 6 3 Switch off the power supply before maintenance Check the power plug connection if found loose fix it properly Do not change any connection position randomly...

Page 27: ...the 8 core 2 core connection line 3 Delay in barrier opening or it doesn t close Cause It may be due to if the time of the barrier opening is set as too long Solution Check whether the time of the op...

Page 28: ...ZKTeco Industrial Park No 32 Industrial Road Tangxia Town Dongguan China Phone 86 769 82109991 Fax 86 755 89602394 www zkteco com Copyright 2021 ZKTECO CO LTD All Rights Reserved...

Reviews: