6. Troubleshooting 

Symptom 

Troubleshooting 

The indicator is not lighted when the 
equipment is powered on. 

It may be caused by the power supply or circuit.   
Check whether the connection cable and power cable between are 
damaged, or the wiring is loose.   

The arms of the tripod turnstile cannot be 
lifted manually after the equipment is 
powered on. 

It may be caused by the problem of relative components or drop-arm 
solenoid. 

1.

 

Check whether the stop base and turn plate withstands each other, 
as shown in Figure 6-1. 

2.

 

Check whether the drop-arm solenoid is operating, and check the 
work status of the solenoid, as shown in Figure 6-2.   

The tripod turnstile does not open after 
authentication. 

It may be caused by lack of permission or a circuit problem. 

1.

 

Check whether the user has the permission to open the turnstile. 

2.

 

Use a multimeter to check whether the NO and COM ports of the 
access control system has a relay signal output. 

3. Short-circuit the ports "K1, GND" and "K2, GND", if the turnstile is 

successfully opened, it would be the problem of controller. In this 
case, please refer to 

Attachment 2 Connection Diagram of Control 

board and Access Control Panel

 to check the cable connection of the 

controller. 

The passing is not smooth after the 
turnstile is opened, it encounters resistance 
when pushing the arms, and the arms 
cannot return to the home position after 
they rotate. 

It is caused by the Adjustable Tension Spring. 
Adjust the Adjustable Tension Spring, as shown in Figure 5-3.   

The arms drop during the use. 

It may be caused by the problem of relative components or drop-arm 
solenoid. 

1.

 

Check whether there is any gap at the position shown in Figure 6-1. 

2.

 

Check whether the drop-arm solenoid is totally closed. If not, power 
off the equipment and power on it again 2 minutes later.   

The turnstile allows people continue 
passing one-way side during the use. 

1.

 

Check the Turnstile-opening Solenoid 

2.

 

Check whether the Turnstile-opening solenoid is operating, and 
check whether the Turnstile-opening solenoid is stuck or the Metal 
Shrapnel is broken, as shown in Figure 5-3. 

 
 

 

Summary of Contents for TS1000 Series

Page 1: ...TS1000 Series Vertical Tripod Turnstile User Manual Version 2 4 Date Jan 2018...

Page 2: ...Degree IP54 Operating Environment Indoor and Outdoor shelter Arm Length mm 520 Operating Temperature 28 C 60 C Net Weight 34kg Operating Humidity 5 85 Gross Weight 40kg Flow Rate 25 30 passages minut...

Page 3: ...1 Please make sure that the power requirements are strictly met to avoid permanent damage to the unit Input voltage AC 100 120V 200 240V Note The tripod turnstile must be connected to the ground eart...

Page 4: ...3 Setting a warning line for card swiping see Figure 3 2 A warning line is suggested to prompt users to swipe cards in a distance which would greatly reduce the probability of equipment failure cause...

Page 5: ...levelness of the mounting plate If the mounting plate is not level adjust it by the gaskets provided Note that all the four expansion bolts must be installed properly as shown in Figure 3 4 Figure 3...

Page 6: ...nd display the number of people passed that is generated by the push of tripod arms each completed push means pass one time J5 Right J4 Left Indicator To connect a LED screen and indicate whether this...

Page 7: ...t otherwise will damage the control board 4 3 DIP K1 switch configuration Figure 4 3 Pin 1 2 3 4 5 6 7 8 Function Setting Opening Duration Direction Indicator Continue Passing Function Alarm Default 1...

Page 8: ...Alarm function optional In the DIP K1 switch number 8 is used to enabled or disabled the Alarm Function 1 enabled 0 disabled Note Please set to 0 when working normally that is to say that Alarm Funct...

Page 9: ...ous positions for prompting passers by to pass in a proper way and in good order Reasonable maintenance consciousness helps to guarantee long term usage of the tripod turnstile Regular maintenance Cle...

Page 10: ...circuit the ports K1 GND and K2 GND if the turnstile is successfully opened it would be the problem of controller In this case please refer to Attachment 2 Connection Diagram of Control board and Acc...

Page 11: ...IP 192 168 1 201 5 Turnstile Opening Duration 5s 6 Passing Direction Indicator Passing is allowed in both directions 7 Continue Passing Function Disabled 8 Alarm Function Disabled Note The Lock Drivin...

Page 12: ...tion Diagram of Control board and Access Control Panel Warning This is a class A product In a domestic environment this product may cause radio interference in which case the user may be required to t...

Reviews: