5
4. Cable Diagram
4.1 Function description of the turnstile control board
If you are using TS1011 or TS1022, all the connections between access control and turnstile control boards are done in
factory. Just plug in communication cable to access controller and do the setting.
If you are using TS1000, you need to connect access control system to the control board, please check the content in this
chapter carefully.
Warning:
The third party access control system lock relay trigger time should be 1 second or less than 1 second.
Figure 4-1
Descriptions:
J2 Counter:
To connect a LED screen and display the number of people passed that is generated by the push of tripod arms,
each completed push means pass one time.
J5 (Right) & J4 (Left) Indicator:
To connect a LED screen and indicate whether this passage is allowed to pass.
J3 Indicator (top):
To connect a LED screen and indicate if user verification is successful and whether it is able to pass.
J-NC2 Disabled Turnstile:
Short circuit NC1 and GND, the turnstile is disabled, that is to say, the turnstile is locked by force.
J7 Opening Signal Input:
To receive relay signal and open the turnstile.
S
hort circuit K1 and GND, left passing is allowed;
short circuit K2 and GND, right passing is allowed.
J6 External Alarm:
Short circuit ALARM1 and GND, and the turnstile is disabled (locked) and the alarm is ringing in case
there are emergencies.