J6 Drop Arm: 

Short circuit DOW and GND, the arm is dropped down by force in case there are fires or other emergencies. 

J8 Proximity Switch Signal Input: 

Input position signal of the arm. 

J9 12V Power Supply for Access control: 

control board directly provide Access Control with 12V power. (Maximum 

support 3A) 

V1L Left Solenoid, V2R Right Solenoid & UP D50 Solenoid: 

Control the passage and arm dropping. 

 

4.2 Connection diagram of the access controller device 

 

Figure 4-2 

Warning: Forbidden using an electrically charged objects to connect to any one port of Opening Signal Input, 

otherwise will damage the control board.

 

 

4.3 DIP K1 switch configuration 

 

Figure 4-3 

Pin 

Function Setting 

Opening Duration  Direction Indicator  Continue Passing Function  Alarm 

Default 

 

4.3.1 Setting the turnstile opening duration 

Opening duration refers to the period of time from opening to closing once the turnstile receives an open signal. In the DIP 
switch, number 1, 2, and 3 are used for duration setting. It can be set to different values from 5s to 60s according to the 
following chart. 

Bit Setting 

Duration 

Bit Setting 

Duration 

111 

5s 

011 

30s 

110 

10s 

010 

40s 

101 

15s 

001 

50s 

100 

20s 

000 

60s 

Note: 

The turnstile opening duration is set to 5s by default. 

 

Note: 

The lock relay duration of access 

controller device needs to be set to 1s.   

Summary of Contents for TS1000 Series

Page 1: ...TS1000 Series Vertical Tripod Turnstile User Manual Version 2 4 Date Jan 2018...

Page 2: ...Degree IP54 Operating Environment Indoor and Outdoor shelter Arm Length mm 520 Operating Temperature 28 C 60 C Net Weight 34kg Operating Humidity 5 85 Gross Weight 40kg Flow Rate 25 30 passages minut...

Page 3: ...1 Please make sure that the power requirements are strictly met to avoid permanent damage to the unit Input voltage AC 100 120V 200 240V Note The tripod turnstile must be connected to the ground eart...

Page 4: ...3 Setting a warning line for card swiping see Figure 3 2 A warning line is suggested to prompt users to swipe cards in a distance which would greatly reduce the probability of equipment failure cause...

Page 5: ...levelness of the mounting plate If the mounting plate is not level adjust it by the gaskets provided Note that all the four expansion bolts must be installed properly as shown in Figure 3 4 Figure 3...

Page 6: ...nd display the number of people passed that is generated by the push of tripod arms each completed push means pass one time J5 Right J4 Left Indicator To connect a LED screen and indicate whether this...

Page 7: ...t otherwise will damage the control board 4 3 DIP K1 switch configuration Figure 4 3 Pin 1 2 3 4 5 6 7 8 Function Setting Opening Duration Direction Indicator Continue Passing Function Alarm Default 1...

Page 8: ...Alarm function optional In the DIP K1 switch number 8 is used to enabled or disabled the Alarm Function 1 enabled 0 disabled Note Please set to 0 when working normally that is to say that Alarm Funct...

Page 9: ...ous positions for prompting passers by to pass in a proper way and in good order Reasonable maintenance consciousness helps to guarantee long term usage of the tripod turnstile Regular maintenance Cle...

Page 10: ...circuit the ports K1 GND and K2 GND if the turnstile is successfully opened it would be the problem of controller In this case please refer to Attachment 2 Connection Diagram of Control board and Acc...

Page 11: ...IP 192 168 1 201 5 Turnstile Opening Duration 5s 6 Passing Direction Indicator Passing is allowed in both directions 7 Continue Passing Function Disabled 8 Alarm Function Disabled Note The Lock Drivin...

Page 12: ...tion Diagram of Control board and Access Control Panel Warning This is a class A product In a domestic environment this product may cause radio interference in which case the user may be required to t...