6
Troubleshooting
Symptom
Troubleshooting
The indicator is not lit
when the equipment is
powered on.
It may be caused by the power supply or circuit.
Check whether the connection cable and power cable are damaged, or
whether the wiring is loosed.
The arms of the tripod
turnstile cannot be lifted
manually after the
equipment is powered on.
It may be caused by the problem of related components or drop-arm
solenoid.
Check whether the drop-arm solenoid is operating, and check the working
status of the solenoid, as shown in Figure 5-2.
The tripod turnstile does
not grant an access after
successful authentication.
It may be caused by lack of permission or a circuit problem.
Check whether the user has the permission to pass.
Use a multimeter to check whether the NO and COM ports of the
access control system have a relay signal output.
Short-circuit the ports "K1, GND" and "K2, GND"; if the turnstile is
successfully opened, the controller is not normal. In this case, please
refer to
Attachment 2 Connection Diagram of Control board and
to check the cable connection of the controller.
The turnstile allows people
to continuously passing
one-way side.
Check the turnstile-opening solenoid.
Check if the access controller "Lock driving duration" is set to 1s.
Check whether the turnstile-opening solenoid is operating and check
whether something is stuck at the turnstile-opening solenoid, as
shown in Figure 5-2.
Turnstile-opening Solenoid
Lock Rod
Drop-arm
Solenoid
Position Sensor
Disk Wheel