background image

TS200 Series Tripod Turnstile

 

 

 

 

 

 

                            

User Manual 

P a g e

 | 8 

 

 

4.2.2

 

Opening Mode 

Card swiping means that you can open the door only after verification. Free means that you can pass the 
door without verification. Prohibited means that you can't pass the door, whether you have permission or 
not. 

4.2.3

 

Opening Duration 

This function refers to the period of time from opening to closing once the turnstile receives an opening 
signal. In the DIP switch, number 3 is used for duration settings. It can be set two different values: 5s or 10s. 

4.2.4

 

Continue Passing Function 

With the "Continue Passing" function, the turnstile could remember at most 20 swipes of one card at one 
time and allows up to 20 people to pass so they don't have to swipe card each time. This function can be 
enabled or disabled with number 4 in the DIP switch.  

5

 

Equipment Precautions and Maintenance 

 

Precautions 

5.1

 

It is recommended to purchase additional accessories to use the product outdoors. 

1)

 

You may install cooling fans for the equipment if the working temperature is often above 50 ºC. 

2)

 

The device is rated IP54 waterproof under proper installation. However, its ability to stand in 
extreme weather conditions, such as typhoon, is not guaranteed. 

3)

 

If the temperature is around or below -30

º

C, you are recommended to install a heating plate for 

the equipment. You might need to turn the power on multiple times to let the device 
automatically heat up through the self-check program. 

4)

 

The service life of this equipment may be shortened if it works outdoors in coastal areas or a 
region prone to acid rain. 

 

If the power and signal cables are connected properly, this equipment can be immersed under water 
at a depth of 250 mm, but it must not be powered on when it is immersed in water. 

 

It is highly recommended to set a warning card-swiping line to remind passers-by to correctly swipe 
cards at a reasonable distance from the device to prevent passers-by from being squeezed. 

 

It is recommended to place a warning sign at a conspicuous position, and prompt: "

Please swipe 

your card outside the warning line and pass in order. Thank you!

 " 

 

 

Summary of Contents for TS1000D

Page 1: ...TS200 Series Tripod Turnstile User Manual P a g e 1 User Manual TS200 Series Tripod Turnstile Date December 2021 Doc Version 1 2 English ...

Page 2: ... CABLING 5 3 2 INSTALLATION 6 3 3 4 CABLE DIAGRAM 7 CONNECTION DIAGRAM OF THE ACCESS CONTROLLER 7 4 1 DIP SWITCH CONFIGURATION FOR SATT L V1 1 7 4 2 4 2 1 FUNCTION INTRODUCTION 7 4 2 2 OPENING MODE 8 4 2 3 OPENING DURATION 8 4 2 4 CONTINUE PASSING FUNCTION 8 5 EQUIPMENT PRECAUTIONS AND MAINTENANCE 8 PRECAUTIONS 8 5 1 MAINTENANCE 9 5 2 6 TROUBLESHOOTING 10 ATTACHMENT 1 FACTORY SETTINGS 11 ATTACHMEN...

Page 3: ...ifications Input Voltage AC 100 120V 200 240V 50Hz 60Hz Arm Length mm 580 Operating Environment Indoor and Outdoor shelter Dimension mm Figure 1 L 1200 W 280 H 980 Operating Temperature 28ºC 60ºC Package Size mm L 1275 W 370 H 1063 Operating Humidity 5 85 Flow Rate Max 30 passages minute Input Control Signal Dry Contact Rated Power 18 W Figure 1 ...

Page 4: ...then tighten 3 hex screws as shown in Figure 2 1 Figure 2 1 Power on Test before Installation 2 2 1 Please make sure that the power requirements are strictly met to avoid permanent damages to the unit Input voltage AC 100 120V 200 240V Note The tripod turnstile must be connected to the ground earth 2 Power on and wait 30s for the tripod turnstile to finish the self check program 3 Lift the arms ma...

Page 5: ...an assistant framework or fence to form a passageway as shown in Figure 3 1 Figure 3 1 Notes 1 When installing the tripod turnstile against the wall please reserve a distance of at least 100 mm in order to open the cover for future adjustment and maintenance 2 The spare space from the end of the arm shall not be greater than 80 mm see Figure 3 1 There is a power switch in the side direction of thi...

Page 6: ...ity of equipment failure caused by improper operations Figure 3 2 Cabling 3 2 There are inlets in the bottom plate for cabling as shown in Figure 3 3 Units of all data is millimeter Power supply and communication wire should go through the inlet Cable protection covers are suggested to use if it is surface mounted Warning The tripod turnstile must be connected to the ground earth there is wiring i...

Page 7: ...nd use a horizontal ruler to test the levelness of the mounting plate If the mounting plate is not levelled adjust it with the gaskets provided Note that all the four expansion bolts must be installed properly as shown in Figure 3 4 Figure 3 4 Install the turnstile on the mounting plate and tighten the screws Apply screw securing glue before using and putting gaskets on the screws to adjust the di...

Page 8: ...ally charged objects to connect to the port of Opening Signal Input otherwise will damage the control board DIP Switch Configuration for SATT L V1 1 4 2 Figure 4 2 4 2 1 Function Introduction No Function Setting Bit Setting Tips 1 2 Opening Mode 00 default Two way Swipe 10 Left Free Right Swipe 01 Left Swipe Right Free 11 Two way Prohibited 3 Opening Duration 0 10S 1 default 5S 4 Continue Passing ...

Page 9: ...utdoors 1 You may install cooling fans for the equipment if the working temperature is often above 50 ºC 2 The device is rated IP54 waterproof under proper installation However its ability to stand in extreme weather conditions such as typhoon is not guaranteed 3 If the temperature is around or below 30º C you are recommended to install a heating plate for the equipment You might need to turn the ...

Page 10: ...se lift the arms manually after at least 6 seconds after power restoration Maintenance 5 2 Forming maintenance consciousness The tripod turnstile needs to be maintained regularly and repaired once it is damaged It is recommended placing warning signs at conspicuous positions for alerting every passersby to pass carefully and in good order Reasonable maintenance consciousness helps to guarantee lon...

Page 11: ... be caused by lack of permission or a circuit problem Check whether the user has the permission to pass Use a multimeter to check whether the NO and COM ports of the access control system have a relay signal output Short circuit the ports K1 GND and K2 GND if the turnstile is successfully opened the controller is not normal In this case please refer to Attachment 2 Connection Diagram of Control bo...

Page 12: ...cation TCP IP 192 168 1 201 5 Turnstile Opening Duration 5s 6 Passing Direction Indicator Passing is allowed in both directions 7 Continue Passing Function Disabled 8 Alarm Function Disabled Note The Lock Driving Duration is 5 seconds by default Please set it to 1 second Do not connect an electrically charged objects to any ports of Opening Signal Input otherwise it will damage the control board ...

Page 13: ... g e 12 Attachment 2 Connection Diagram of Control Board and Access Control Panel Warning This is a class a product In a domestic environment this product may cause radio interference so that the user may have to take adequate additional measures ...

Page 14: ......

Reviews: